Page
53
of
62
Metro (Konica Head)
12.
Do’s and Don’t
Do
’
s
1.
Keep the room dust free and maintain the temperature between 25°C and 28°C
2.
Water filter plates should be fitted when jetting pump is on
3.
Always care about the wrinkles on fabric, it may damage the Print Heads
4.
Conveyor belt shifting has to be monitored regularly and also adjusted with the help of adjusting
roller
5.
Maintain the water level in the water tank and refresh water every 3-4 hours
6.
Add 2 spoons of
Caustic Soda
in every water recycle in tank
7.
To avoid air in head pipes, always maintain the ink level more than 1 Liter in the main tank and
wipe the Print Heads immediately after purging
8.
Water tank filter plates should be cleaned every hour to remove stuck threads and also to avoid
overflow
9.
Always use the clean and fresh water for washing system for longer life of related parts
10.
It’s time for tub maintenance
, if:-
a.
Jetting pipe have choked nozzles
b.
When brush roller is filled with threads
c.
When sponge roller is not moving and has become slippery
11.
When belt has shifted out of the roller
a.
Do not give next print command
b.
Remove fabric from the belt
c.
Move the belt in the reverse direction with the help of Glue Cycle
d.
After belt is in center, adjust the shifting control knob/roller slightly as taught
Don’ts
1.
Don’t wipe
(only blot) the Print Head with tissue paper or cloth piece as it may damage the head
nozzles
2.
Never remove the water filter plates, when jetting pump ON
3.
Never keep the printing continue, if the belt has shifted more
4.
Don
’
t run the belt without jetting ON
5.
Don
’
t run the jetting pump when water tank is empty
6.
Don’t switch
OFF the printer without making the tub down
7.
Don’t leave the
Print Heads without capped
8.
Don’t
move the carriage over the Capping Station when printer is OFF and capping is in UP position
9.
Don
’
t print when glue layer is not smooth/peeled OFF