![COLO COLO-660 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/colo/colo-660/colo-660_operating-instruction_2637562012.webp)
12
TROUBLES
Problem
Cause
Measure
High
–voltage
display
does
not
operated even after
powder is on and
trigger is pulled
. Electric faulty-The electric line coming
into CONTROL UNIT is not property
connected
. Faulty fuse and bad equipemnt on
the part of external power source .
.Faulty lamp.
.Faulty printed circuit board(PCB)
.Faulty line in GUN
.Faulty in high-voltage generation part
.Faulty trigger switch
. connect the power
Replace
Preplace
Preplace
Preplace
Preplace
Preplace
Preplace
The powder would
not be fluidified
.The fluidzing air hose is not
connected or compressed air is not
input
. Faulty fluidizing plate
. Faulty operation of pressure reduction
valve
.Connect after checking
.Replace
.Replace
The gauge hands of
CONVERYING
AIR
and DOSING AIR do
not
move
during
operation
.operation mistake:
The power switch is not pressed
.The trigger is not pulled
.Faulty SOLENOID valve
.Faulty PCB
. Turn on the power switch
.Check while pulling the
trigger
. Replace
Содержание COLO-660
Страница 1: ...1 Operating instruction Model No COLO 660 ...
Страница 3: ...3 Drawing of connection FRONT OF CONTROL UNIT BACK OF CONTROL UNIT ...
Страница 4: ...4 Simple description ...