COLO COLO-660 Скачать руководство пользователя страница 12

 

12 

TROUBLES   
 

Problem   

Cause   

Measure   

High 

–voltage 

display 

does 

not 

operated  even  after 

powder  is  on  and 

trigger is pulled 

. Electric faulty-The electric line coming 

into CONTROL UNIT is not property 

connected   

. Faulty fuse and bad equipemnt    on 

the part of external power source . 

.Faulty lamp. 

.Faulty printed circuit board(PCB) 

.Faulty line in GUN   

.Faulty in high-voltage generation part   

.Faulty trigger switch   

 

. connect the power   

 

 

 

Replace   

Preplace   

Preplace   

Preplace   

 

Preplace   

 

Preplace   

 

Preplace   

 

The  powder  would 

not be fluidified   

.The fluidzing air hose is not   

connected  or  compressed  air  is  not 

input   

. Faulty fluidizing plate   

. Faulty operation of pressure reduction 

valve   

.Connect after checking   

.Replace   

.Replace 

The  gauge  hands  of 

CONVERYING 

AIR 

and  DOSING  AIR  do 

not 

move 

during 

operation   

.operation mistake: 

The power switch is not pressed   

.The trigger is not pulled   

.Faulty SOLENOID valve   

.Faulty PCB   

. Turn on the power switch   

.Check  while  pulling  the 

trigger   

. Replace   

 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание COLO-660

Страница 1: ...1 Operating instruction Model No COLO 660 ...

Страница 2: ... converying air and the dosing air is to be requlated on the control module the fluidizing air on the peneumatic unit The powder is fluidized by forcing air from bleow truough a proous plastic plate The fluidized powder gets liguld like properties Technical Data Power range 110V 220v Frequency 60HZ 50HZ Temperature range in use 10 50 Powder Gun Gun weight 500G Rated output voltage 24VDC Maximum ou...

Страница 3: ...3 Drawing of connection FRONT OF CONTROL UNIT BACK OF CONTROL UNIT ...

Страница 4: ...4 Simple description ...

Страница 5: ...readed sleeve 500104 Hook 500105 Back cover 500106S Deflector 14mm 500106B Deflector 19mm 500107F Electrode holder flat jet nozzle 500107R Electrode holder round jet nozzle 500108 Trigger 500109 Trigger cover 500110 O ring 500112 Hose connection 500113 Cable 500115 micro switch ...

Страница 6: ...n no use condiction MAINTENANCE Make a periodic confirmation of grounding to earh of all equipment in the spray area Exercise good housekeeping practices do not allow dirt or powder to accumulate on the feeder powder unit cable or gun Keep the cabinet door PERSONNEL Use saop and water to remove powder from the skin washing with solvents can cause reactions resulting in allergies and disourders Was...

Страница 7: ... pair of grounded shoes 2 The floor of workplace shoud be conducted 3 All condusction material with 5 meters around powder booth are completely grounded 4 Fact the GUN to dircetion of BOOTH and not to the human body 5 In case of powder such as spaying paint dust density of 10g m3 Or more could cause explosion and the internal booth should be maintained in good and clean condition CHECK FUNCTION OP...

Страница 8: ...ll the trigger 5 Adjust the high voltage to the required level the level can be monitored by a meter 6 Wait unitl the first spayed powder comes out completely dried 7 Proceed with spraying object to be powder coated 2 Taking stop spraying measure 1 release the GUN S trigger 2 turn off the power switch as the powder is still fluid you shouldnot adjust the amount of high voltage Cleaning air and pow...

Страница 9: ...mount of AIR for uniform boiling 3 close the lid B The amount of powder output and control The amount powder output is determined by powder type the length and diameter of hose and the amount of CONVERYING AIR and DOSING AIR 1 check the powder is normally fluidizied 2 turn on the power switch 3 pull the trigger with the GUN facing to the direction to BOOTH 4 Open the CONVERYING AIR 5 Adjust the DO...

Страница 10: ...heck cleans the hopper injector and GUN powder should not be put in the hopper just before work check the ground line between CONTROL UNIT BOOTH and CONVERYOR After checking air dehydrator any water in it should be removed the air but for checking the presence of moisture in it C Checking for shutdown lasting 2 3 days 1 Turn off the power switch 2 Clean the CONTROL UNIT 3 Remove the imput air and ...

Страница 11: ...Electrostatic GUN Rountine cleaning of GUN ensures trouble free operation and normal function at all times Daily clearning 1 Remove the powder hose from gun 2 remove nozzle from GUN and clean it 3 Clean the gun s powder outlet with AIR along the direction of its flow 4 clean the gun s body with AIR 5 Assemble it C Spray Nozzle Dairly cleaning clean the outer surface of nozzle with compressed air D...

Страница 12: ...art Faulty trigger switch connect the power Replace Preplace Preplace Preplace Preplace Preplace Preplace The powder would not be fluidified The fluidzing air hose is not connected or compressed air is not input Faulty fluidizing plate Faulty operation of pressure reduction valve Connect after checking Replace Replace The gauge hands of CONVERYING AIR and DOSING AIR do not move during operation op...

Страница 13: ...e issues Replace Replace Replace Install an air dehydrator Powder is ejected from GUN but with its electrostatic intensity low High voltage assembly is low Faulty GUN connector wire and wire connector Faulty PCB Faulty high voltage casecade Faulty ROD holder increase the voltage leverl Replace the faulty part Replace Replace Powder ejection and electrostatic intensity is good but its attach effici...