Collomix GmbH
RotoGen 1000
85080 Gaimersheim
Version 3.1-17
9
3.5
Holding elements
The RotoGen 1000 is equipped with interchangeable holding elements and adapters for enabling toner pots, mixing cups and other
containers from different manufacturers to be used for mixing.
Make sure that you always use the right element/adapter for the respective mixing cup system.
The use of an unsuitable holding element may lead to damage to the machine and/or incomplete
homogenization!
Holding element and adapter for 3M
TM
PPS
•
PPS – 700 ml
•
PPS – 900 ml
+
# 72225
# 62997
•
PPS –200 ml
+
# 72225
# 72231
Holding element and adapter for SATA
®
RPS
•
RPS – 900 ml
•
RPS – 600 ml
+
# 72225
# 62996
•
RPS – Sata Mini 300 ml
+
# 72225
# 72238
Holding element for mixing toner pots
(Glasurit, DuPont, Spies Hecker, Standox, among others)
•
Toner pot, 0.5 l, metal/plastic, diameter 110mm ±1.5mm
•
Toner pot, 1.0 l, metal/plastic, diameter 110mm ±1.5mm
# 72225
# 62997
•
Plastic bottle, 0.125 ml (Glasurit/R-M)
+
# 72225
# 72229
•
Laboratory cup, 300 ml
+
# 72225
# 72230
Pull out the holding element you wish to replace from the quick-change mount. Insert the new holding element in the
quick-change mount, turn it until you feel it latch in and then press until it is fully locked in place.