ROTA X.40
Collomix GmbH
16
Version 1.1-20
8.
Maintenance
It is necessary to check, clean, and service the machine regularly to ensure continuous function.
Unplug the machine from power by pulling the plug before all cleaning, maintenance, and repair
work is done on the machine
.
Use protective gloves to avoid injuries on sharp edges when working inside the machine
8.1
Cleaning
Remove any spilled mixed compound
immediately
from the interior of the machine. For this purpose,
use a rag or a scraper. Be careful not to damage any connections or sensors.
After cleaning the splash guard, apply a thin film of spray oil to avoid any sticking of colour splashes.
8.1.1
Weekly cleaning
Check lower
②
and upper clamping plate
③
, remove any dirt if necessary.
Check the function of the integral door
⑧
and remove any paint from the door guide so that the
door slides and closes easily.
Check the handle fixation
⑨
for wear and tear. Replace if necessary.
CAUTION
Damage to the machine through wrong cleaning
•
Never use solvent cleaning agents such as acetone, gasoline, or similar aggressive substances
to clean the door window or the control panel. Such substances can corrode or even destroy
plastic parts.
•
Never clean the machine with a high-pressure cleaner or water hose! This washes out the
grease lubrication of the ball bearings and promotes corrosion.
8.2
Service
Only qualified personnel may carry out maintenance and repair work. Use only original replacement
parts.
8.2.1
Annual service
Clean the threaded spindles and lubricate with Mobilux EP2.
Check the timing belt for wear and tear.
Check the door lock, locking mixing unit and spring contacts. Adjust if needed.
Check the clamping plates
② and ③
for wear and tear. Replace if needed.
8.2.2
Runtime-dependent service
The timing belt of the mixing unit must be replaced by an authorized service technician every 30,000
mixing cycles but no later than after 1,000 operating hours.
The number of cycles and the operating hours are shown on the LC display of the operating unit during
the initialization after the machine is turned on.
②
Lower clamping plate
③
Upper clamping plate
⑧
Integral door
⑨
Handle fixation
③
②
⑧
⑨