Collomix GmbH
Rotation mixer
85080 Gaimersheim
AOX-S
Art.no. 37125
Rev. 3
Page 7
Commissioning
The device is delivered ready for operation in carton packaging. The net weight is 112.5 lb.
The machine and power cable must always be checked for damage prior to commissioning.
Check that the mixing tool is mounted correctly.
Check that the voltage indicated on the type plate matches the mains voltage.
Connect the machine connector to the power supply socket using a suitable extension cord (typeSJNW
3x13 AWG. It must be fitted with a residual current interruption system (RCD e.g. earth leakage circuit
breaker).
A deduster can be connected to the mixer via the Ø 35 mm / 1.38” adapter to reduce the dust load that
personnel are exposed to on the construction site. This deduster should be equipped with a fine filter
system to stop the dust accordingly.
Operation
X
When the device is in an open state, fill the mixing bucket with water and the mixing material.
X
Press the
green START button "I"
– the mixing bucket will start to turn.
X
Fold down the swivel arm with the mixing tool and submerge it in the mix; the mixing tool starts.
Through the rotation of the bucket, the mix is guided to the mixing tool.
X
Press the
red OFF button "0"
to terminate the mixing process. The machine stops.
X
Alternatively: The mixing tool drive is switched off as soon as the swivel arm is lifted. The bucket
continues to turn. Switch it off via the red STOP button "0".
X
IMPORTANT!
Please remove the full bucket using the trolley (accessory). Do not lift the full bucket out of the
machine by yourself.
X
Change the mixing tool with an open-end wrench on the hexagonal holding fixture of the tool and
position on the agitator shaft and remove.
X
The recommended fill level of the mixer is dependent on the density and viscosity of the material.
A test mixture is recommended in individual cases.
X
The bucket including the ready-mixed material can be lifted out of the machine using a trolley and
can then be moved to the intended location.
WARNING
Risk of injuries due to rotating mixing tool.
Do not reach into the mixing drum or handle tools in the mixing drum during mixing.
The machine must only be used with the mixing bucket provided.
Mains plug
Deduster connection
ON/OFF switch
Replace the mixing
tool