background image

Please follow the instructions in this manual to obtain the optimum results from this unit.

We also recommend that you keep this manual handy for future reference.

PROJECTMIX818

O

P

E

R

A

T

IO

N

 M

A

N

U

A

L

ZONE SELECT

OUTPUT  LEVEL

FUNCTION

PAGE ALL

ENTER

BGM  ALL

ESC

POWER

MONITOR

SOURCE  UP

SOURCE  DOWN

PAGE BUSYMIC1 PRIORITY

ZONE 1

SOURCE  UP

SOURCE  DOWN

PAGE BUSY MIC1 PRIORITY

ZONE 8

SOURCE  UP

SOURCE  DOWN

PAGE BUSY MIC1 PRIORITY

ZONE 2

SOURCE  UP

SOURCE  DOWN

PAGE BUSY MIC1 PRIORITY

ZONE 3

SOURCE  UP

SOURCE  DOWN

PAGE BUSY MIC1 PRIORITY

ZONE 4

SOURCE  UP

SOURCE  DOWN

PAGE BUSY MIC1 PRIORITY

ZONE 5

SOURCE  UP

SOURCE  DOWN

PAGE BUSY MIC1 PRIORITY

ZONE 6

SOURCE  UP

SOURCE  DOWN

PAGE BUSY MIC1 PRIORITY

ZONE 7

PROJECT

MIX818

MIC 1

MUSIC 

MASTER

MIC 1

MUSIC 

MASTER

MIC 1

MUSIC 

MASTER

MIC 1

MUSIC 

MASTER

MIC 1

MUSIC 

MASTER

MIC 1

MUSIC 

MASTER

MIC 1

MUSIC 

MASTER

MIC 1

MUSIC 

MASTER

EMERGENCY

Содержание PROJECTMIX818

Страница 1: ...RCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 8 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 2 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 3 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 4 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 5 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 6 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 7 PROJECTMIX818 MIC 1 MUSIC MASTER MIC 1 MUS...

Страница 2: ... result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting the unit in ...

Страница 3: ...ating sooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switch...

Страница 4: ...CONTENTS 1 INTRODUCTION 1 2 FRONT PANEL LAYOUT 1 3 REAR PANEL LAYOUT 4 4 RS 485 COMMUNICATION PROTOCOL 9 5 SPECIFICATIONS 10 6 CONNECTION DIAGRAM 11 7 CONNECTION AND SETTING 12 ...

Страница 5: ... 4 remote paging consoles and one microphone input all of these inputs can be freely allocated into different 8 zone outputs simultaneously 2 FRONT PANEL LAYOUT ZONE SELECT OUTPUT LEVEL FUNCTION PAGE ALL ENTER BGM ALL ESC POWER MONITOR SOURCE UP SOURCE DOWN PAGE BUSYMIC1 PRIORITY ZONE 1 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 8 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 2 SOURCE...

Страница 6: ... will mix with lines 1 8 and local inputs if required This Microphone input has been designed to give global priority over all other inputs if enabled via the front panel The MIC1 priority setting is not The Music Volume control knob 6 controls the selected source zones 1 8 and local input input level If the system is used with Remote Control Panels the Music Volume knob will be disabled Source Mu...

Страница 7: ... to select the same source for all 8 zones simultaneously To confirm the BGM ALL selection press ENTER The BGM ALL selection will only be confirmed after the ENTER button is pressed otherwise the source selection will be return to previous setting after 10 seconds In the event power is lost the BGM ALL selection settings will be saved and the unit will return to the previous BGM ALL setting when p...

Страница 8: ...E 350mV MIC 5mV LINE 350mV MIC 5mV LINE 350mV MIC 5mV LINE 350mV 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 dB dB dB dB dB dB dB dB 0 775V 600 0 775V 600 0 775V 600 0 775V 600 0 775V 600 0 775V 600 0 775V 600 0 775V 600 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 300mV 1 1V 10K 115V 230V 50 60Hz 110V 0V 1 3 2 0V 1 3 2 0V 1 3 2 0V 1 ...

Страница 9: ...e This will enable the Line I 8 Sources MIC1 input Paging Consoles I 2 and Communication Data of the master unit to be shared with any Slave Matrix Units connected to the system REAR PANEL LAYOUT PIN 1 24V DC 24V Power supply input Battery Back Up or UPS PIN 2 GROUND DC 24V Power Which is Common for ALERT EVAC Supply input Battery Back Up or UPS PIN3 COMMON An optional external voice alarm message...

Страница 10: ...atrix b A Music level control on the Matrix front panel or the remote wall control c A Master level control on the Matrix front panel Please Note The input signal is set at 300mV 1 lv 1 OK Ohm Local Source Connections are as follows 1 A remote wall panel can be connected to the Matrix with only one remote wall controller able to be connected per zone 2 The remote wall panel will be selectable on t...

Страница 11: ...ndependently of other zones If a Zone Remote Wall Control Panel is to be used with the System The R J45 Remote Control Panel Input needs to be enabled The RJ45 Remote Control Panel Input is enabled disabled by pressing the Enable Disable Switch Every Zone has an RJ45 Remote Control Panel Input Enable Disable Switch Only Enable when a Zone Remote Wall Control Panel is connected The Zone Local Sourc...

Страница 12: ...will be indicated on the Matrix zone display 3 Any extension Matrix unit connected to the system will use sources line 1 8 from the master Matrix 4 Only one set of input sources for lines1 8 can will be connected per system Up to two paging consoles can be connected to the system simul taneously via the two paging con sole Rj45 input ports The paging consoles will have equal priority and will oper...

Страница 13: ...n 2nd data byte 3rd data byte 4th data byte PROJECTMIX818 Inquiry Data ThePROJECTMIX818 sends inquiry data to 2 remote paging consoles 8 remote wall panels and extension Matrix The new data will feed back to the Matrixwhen any new data has been checked Any extension PROJECTMIX818 will only enquire to its own 8 remotewall panels only Inquiry Data To Paging Console The PROJECTMIX818 sends the inquir...

Страница 14: ... Output Level Control S N Ratio Isolation Degree Channel Crosstalk Gain Deviation T H D Channel Phase Position Frequency Response Input 100Hz sine wave signal Conditions Voltage selector between 115V 230V Clockwise rotation gainto increase MIC1 input 80Hz 18KHz 20Hz 20KHz Line1 8inputsandremotesourceinput 20Hz 20KHz 20Hz 20KHz 20Hz 20KHz Non weighting Input 100Hz sine wave signal Balanced output I...

Страница 15: ...PRIORITY ZONE 1 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 8 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 2 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 3 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 4 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 5 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 6 SOURCE UP SOURCE DOWN PAGE BUSY MIC1 PRIORITY ZONE 7 PROJECTMIX818...

Страница 16: ...vidual zone paging or all call actions Please Note Power Supply Connection Between Remote Paging Console Extension Keypad The remote paging console is powered by the Matrix through the RJ45 communication port when the communication distance is 50 meters An extra DC 24V po wer input is equipped on the back part of the paging console to supply power when the communication distance is longer than 50 ...

Страница 17: ...VersionV0 1 ...

Отзывы: