035-19315-001-A-0603
Unitary Products Group
3
LIST OF FIGURES
Fig. #
Pg. #
1
RECOMMENDED DRAIN PIPING . . . . . . . . . . . . . 11
2
COMPRESSOR RESTRAINING BRACKET . . . . . 12
3
TYPICAL FIELD POWER & CONTROL WIRING . 13
4
ENTHALPY SETPOINT ADJUSTMENT . . . . . . . . 17
5
HONEYWELL ECONOMIZER CONTROL W7212 17
6
FOUR AND SIX POINT LOADING . . . . . . . . . . . . . 18
7
UNIT DIMENSIONS (3 - 5 TON HEAT PUMP)
FRONT VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
8
UNIT WITH ECONOMIZER RAINHOOD . . . . . . . . 28
9
UNIT WITH FIXED OUTDOOR AIR/MOTORIZED
DAMPER RAINHOOD . . . . . . . . . . . . . . . . . . . . . . 29
10 UNIT DIMENSIONS (REAR VIEW) . . . . . . . . . . . . 29
11 DISCONNECT/BLOWER ACCESS LOCATION . . 29
12 BELT ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . 34
13 PRESSURE DROP ACROSS COIL . . . . . . . . . . . . 35
LIST OF TABLES
Tbl. #
Pg. #
1
UNIT APPLICATION DATA (BB) . . . . . . . . . . . . . . 10
2
CONTROL WIRE SIZES . . . . . . . . . . . . . . . . . . . . 14
3
ELECTRIC HEATER CFM LIMITATIONS . . . . . . . 15
4
CENTER OF GRAVITY (ALL MODELS) . . . . . . . . 18
5
BB 4 POINT LOADS WEIGHT DISTRIBUTION . . . 18
6
BB 6 POINT LOADS WEIGHT DISTRIBUTION . . . 18
7
PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . 19
8
OPERATING WEIGHTS (LBS.) . . . . . . . . . . . . . . . 19
9
ELECTRICAL DATA - BB-03 & -04 DIRECT DRIVE
WITHOUT POWR’D CONVENIENCE OUTLET . . . 20
10 ELECTRICAL DATA - BB-05 DIRECT DRIVE
WITHOUT POWR’D CONVENIENCE OUTLET . . . 21
LIST OF TABLES (CONT.)
Tbl. #
Pg. #
11 ELECTRICAL DATA - BB-03 & -04 BELT DRIVE
WITHOUT POWR’D CONVENIENCE OUTLET. . . 22
12 ELECTRICAL DATA - BB-05 BELT DRIVE WITHOUT
POWR’D CONVENIENCE OUTLET . . . . . . . . . . . 23
13 ELECTRICAL DATA - BB-03 & -04 DIRECT DRIVE
WITH POWR’D CONVENIENCE OUTLET . . . . . . 24
14 ELECTRICAL DATA - BB-05 DIRECT DRIVE WITH
POWR’D CONVENIENCE OUTLET . . . . . . . . . . . 25
15 ELECTRICAL DATA - BB-03 & -04 BELT DRIVE
WITH POWR’D CONVENIENCE OUTLET . . . . . . 26
16 ELECTRICAL DATA - BB-05 BELT DRIVE WITH
POWR’D CONVENIENCE OUTLET . . . . . . . . . . . 27
17 ELECTRIC HEAT CORRECTION FACTORS . . . . 27
18 VOLTAGE LIMITATIONS . . . . . . . . . . . . . . . . . . . 27
19 UTILITIES ENTRY . . . . . . . . . . . . . . . . . . . . . . . . 30
20 MINIMUM CLEARANCES . . . . . . . . . . . . . . . . . . . 30
21 SUPPLY AIR BLOWER PERFORMANCE (3 TON
BELT DRIVE) - SIDE DUCT APPLICATION . . . . . 30
22 SUPPLY AIR BLOWER PERFORMANCE (4 TON
BELT DRIVE) - SIDE DUCT APPLICATION . . . . . 31
23 SUPPLY AIR BLOWER PERFORMANCE (5 TON
BELT DRIVE) - SIDE DUCT APPLICATION . . . . . 32
24 SUPPLY AIR BLOWER PERFORMANCE (3 - 5 TON
DIRECT DRIVE) - SIDE DUCT APPLICATION . . 33
25 BELT DRIVE BLOWER MOTOR AND DRIVE
DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
26 STATIC RESISTANCES . . . . . . . . . . . . . . . . . . . . 34
27 LIMIT CONTROL SETTING . . . . . . . . . . . . . . . . . 38
28 ELECTRIC HEAT ANTICIPATOR SETPOINTS . . 39
29 UNIT CONTROL BOARD FLASH CODES . . . . . . 42