In Case of Contamination

 

WARNING: THE FOLLOWING PROCEDURE IS INTENDED AS A GUIDE. SHOULD SPILLAGE OF A

 

TOXIC OR HAZARDOUS FLUID OCCUR, THEN ADDITIONAL SPECIAL PRECAUTIONS MAY

 

BE NECESSARY.

If the equipment has been exposed to contamination, the Responsible Body is responsible for carrying out
appropriate decontamination. If hazardous material has been spilt on or inside the equipment, decontamination 
should only be undertaken under the control of the Responsible Body with due recognition of possible hazards. 
Before using any cleaning or decontamination method, the Responsible Body should check with the 
manufacturer that the proposed method will not damage the equipment. Prior to further use, the Responsible 
Body shall check the electrical safety of the unit. Only if all safety requirements are met can the unit be used 
again.

NOTE: 

In the event of this equipment or any part of the unit becoming damaged or requiring service, the item(s) 

should be returned to the manufacturer for repair accompanied by a decontamination certificate. Copies of the 
Certificate are available from the Distributor/Manufacturer.

At the end of its service life, the product must be accompanied by a Decontamination Certificate.

Servicing and Repair

This product range does not require any routine servicing, instructions for cleaning and decontamination are 
included.

In the event of product failure, it is recommended that any repair is only undertaken by suitably qualified 
personnel. For advice, please contact Techne quoting the model and serial number.

Only spare parts supplied by the manufacturer or its agent should be used. Fitting of non-approved parts may 
affect the performance of the safety features of the instrument.

If in doubt, please contact:

Cole-Parmer Ltd.
Beacon Road,
Stone, Staffordshire,
ST15 0SA, United Kingdom
Tel: +44 (0)1785 812121
Email: [email protected]
Web: www.coleparmer.com

Warranty

Cole-Parmer Ltd. warrants this equipment to be free from defects in material and workmanship when used 
under normal laboratory conditions for the period specified on the enclosed warranty card. In the event of a 
justified claim, Cole-Parmer will replace any defective component or replace the unit free of charge.

This warranty does NOT apply if:

  Any repair has been made or attempted other than by the manufacturer or its agent.

v

   Any minor coating chips or scratches occur during normal use (i.e., wear and tear).

v

   Damage is caused by fire, accident, misuse, neglect, incorrect adjustment or repair, damage

 

caused by installation, adaptation, modification or fitting of non-approved parts.

8

Содержание Techne FSC400D

Страница 1: ...Sample Concentrator FSC400D FSC496D Instruction Manual TECH0002 Version 1 0...

Страница 2: ...essing of Samples 8 Maintenance 8 Cleaning and Care 8 Carriage Friction 8 Replacing Sealing Pad 9 In Case of Contamination 9 Service and Repair 10 Warranty 10 Replacement Parts and Accessories 10 Diag...

Страница 3: ...into the test tubes The samples are heated from below by the heater and the flow of gas directed over the surface of the samples displaces the evaporated solvent from above the liquid s surface This s...

Страница 4: ...e carriage Tighten the locking knob to secure the gas chamber in position 3 Connect the intake nozzle at the rear of the gas chamber to a suitable supply of gas via a pressure reducing valve The gas p...

Страница 5: ...F3506 you would place a needle in all the holes labelled C Only Sample Concentrators with the part number FSC496D or a replacement head part number 6106467 will have the 96 well array Tube size diamet...

Страница 6: ...FSC400D matrix plate FSC496D matrix plate Inserting the Needles 6...

Страница 7: ...the product and could cause a hazard Preventative maintenance should include keeping the product clean by protecting it from spillage contamination or corrosive environments If in doubt please confirm...

Страница 8: ...ntamination Certificate Servicing and Repair This product range does not require any routine servicing instructions for cleaning and decontamination are included In the event of product failure it is...

Страница 9: ...F7210 Pack of 100 x 127mm long needles FSC4NCS Pack of PTFE coated needles 100 x 76mm long FSC4NCL Pack of PTFE coated needles 100 x 127mm long 6101608 Spigot 6101604 Sealing pad 6101605 Support strip...

Страница 10: ...e diameter 6 35 mm Height 530 mm Width 240 mm Depth 295 mm Weight 3 5 Kg Customer and Technical Support For help and support contact Cole Parmer Ltd Beacon Road Stone Staffordshire ST15 0SA United Kin...

Страница 11: ...acid Ethanoic acid 118 44 Ethanol Alcohol 79 175 Ethyl acetate Ethyl ester 77 40 Heptane Dipropylmethane 98 120 Hexane n Hexane 69 335 Propan 2 ol Isopropanol 82 137 3 Methyl 1 butanol Isoamyl alcohol...

Страница 12: ...g the details below UK Office Keison Products P O Box 2124 Chelmsford Essex CM1 3UP England Tel 44 0 330 088 0560 Fax 44 0 1245 808399 Email sales keison co uk Please note Product designs and specific...

Отзывы: