2.5 Environment, storage and use

• 

Maximum altitude: 2000 m

• 

Pollution degree: 2

• 

This product is a precision instrument and it should be used in a proper environment for optimal use

• 

Install your product indoors on a stable, vibration free and level surface in order to prevent this instrument to 
fall thereby harming the operator

• 

Do not place the product in direct sunlight

• 

The ambient temperature should be between 5 to +40°C and humidity should be within 20 to 80% RH

• 

Although the system is anti-mold treated, installing this product in a hot, humid location may still result in the 
formation of mold or condensation on lenses, impairing performance or causing malfunctions

• 

Never turn the right and left focus knobs in opposite directions at the same time or turn the coarse focus knob 
past its farthest point as this will damage this product

• 

Never use undue force when turning the knobs

• 

Make sure that the microscope system can dissipate its heat (fire hazard)

• 

Keep the microscope away from walls and obstructions for at least approximately 15 cm

• 

Never turn the microscope on when the dust cover is in place or when items are placed on the microscope

• 

Keep flammable fluids, fabric, etc. well out of the way

Disconnect power

Always disconnect your microscope from power before doing any maintenance, cleaning, assembling or replacing 
LEDs to prevent electric shocks

Prevent contact with water and other fluids

Never allow water or other fluids to come in contact with your microscope, this can cause short circuiting your device, 
causing malfunction and damage to your system

Moving and assembling

• 

This microscope is a relatively heavy system, consider this when moving and installing the system

• 

Always lift the microscope by holding the main body and base of the microscope

• 

Never lift or move the microscope by its focusing knobs, stage or head

• 

When needed, move the microscope with two persons instead of one

3. Models 

The MSS-200 Series is available in two different models, with a choice of stand. They are equipped with 45° inclined 
tubes and a zoom system with a pair of widefield WF 10x/21 eyepieces. 

Model

Type

Magnification

Working distance

Stand

Illumination

Power

Weight

78904-66

Trinocular

0.7 to 4.5x

100 mm

Pillar

Incident (3 W LED);  

transmitted (3 W LED)

100–240 VAC, 

50/60 Hz

10.4 lb (4.2 kg)

78904-69

Trinocular

0.7 to 4.5x

100 mm

Rack & pinion

Incident (3 W LED);  

transmitted (3 W LED)

100–240 VAC, 

50/60 Hz

7.3 lb (3.3 kg)

5

Содержание 78904-66

Страница 1: ...Installation and Operating Instructions MSS 200 Series Trinocular Stereozoom Microscopes Models 78904 66 69 78904 66 78904 69...

Страница 2: ...ctives________________________________________________________________________________ 7 4 4 Object stage ______________________________________________________________________________ 7 4 5 Focusing_...

Страница 3: ...with a cover glass never comes in direct contact with the microscope parts In that case prevention of contamination lies in the handling of the slides as long as the slides are decontaminated before...

Страница 4: ...based disinfection products for laboratories Before returning a microscope for repair or maintenance through a Cole Parmer dealer an RMA return authorization form together with a decontamination state...

Страница 5: ...when items are placed on the microscope Keep flammable fluids fabric etc well out of the way Disconnect power Always disconnect your microscope from power before doing any maintenance cleaning assemb...

Страница 6: ...smitted illumination G Object plate with transmitted illumination below it H Stand base I Handle J Photo port K Microscope head L Stand rack pinion version M Focusing knobs only one is visible N Incid...

Страница 7: ...n stands and pillar stands are equipped with an object stage with a semi transparent stage plate G and two object clips N 4 5 Focusing With the two coarse focusing knobs M the object can be sharply fo...

Страница 8: ...ching the tubes The eyepieces can be secured with a screw The exact location of the hexagon screw may differ Each eyepiece has a rubber eyeshade This prevents damage to the lens and stray light The ey...

Страница 9: ...t knob to the lowest magnification Rotate the focusing knob to bring the specimen into focus Turn the zoom adjustment knob to the highest magnification Rotate the focusing knob to bring the specimen i...

Страница 10: ...w through the eyepieces Adjustment can be made by raising lowering the height of the camera C Take an easy to view specimen and focus the image through the microscope s eyepieces with dioptre adjustme...

Страница 11: ...the fuse compartment which has a fuse image It is typically located close to the power connector Remove the fuse compartment To do so insert a flat head screwdriver behind the fuse compartment and gen...

Страница 12: ..._________________________________________________________________ ___________________________________________________________________________________________________ __________________________________...

Отзывы: