manualshive.com logo in svg
background image

OPERATING MANUAL: 

FH10
Pump System

®

Model 77720-00

Model Nos.

77720-00
77720-02
77720-04

A-1299-7290

Edition 01

(US & Canada only) Toll Free 1-800-MASTERFLEX • 1-800-637-3739
(Outside US & Canada) 1-847-549-7600 • 1-847-381-7050
E-mail: [email protected]
www.masterflex.com • www.coleparmer.com

Содержание 77720-00

Страница 1: ...77720 00 Model Nos 77720 00 77720 02 77720 04 A 1299 7290 Edition 01 US Canada only Toll Free 1 800 MASTERFLEX 1 800 637 3739 Outside US Canada 1 847 549 7600 1 847 381 7050 E mail techinfo coleparmer com www masterflex com www coleparmer com ...

Страница 2: ...rights reserved NORYL Reg TM General Electric Company C FLEX PHARMED TYGON Reg TM Saint Gobain Performance Plastics Corp VITON Reg TM E I duPont DeNemours Co These products are covered by one or more of the following U S and corresponding foreign patents D605 286S Trademarks bearing the symbol in this publication are registered in the U S and in other countries PUMP FOR LIQUIDS ORIGINAL INSTRUCTIO...

Страница 3: ...nty Do not pull the tubing too tight Do not pinch the tubing to cause it to be closed off CAUTION Risk of Danger Consult Operator s manual for nature of hazard and corrective actions CAUTION Risk of crushing Keep fingers away from rotor while pump is in operation Stop pump before loading or unloading tubing CAUTION Hot Surface Do not touch CAUTION Risk of electric shock Consult Operator s manual f...

Страница 4: ......

Страница 5: ...ion 2 4 OPERATION 3 1 Turning Pump System On and Selecting Direction of Operation 3 1 Setting Pump Speed 3 1 Priming Pump System 3 1 MAINTENANCE 4 1 Cleaning 4 1 REPLACEMENT PARTS and ACCESSORIES 5 1 Replacement Parts 5 1 Accessories 5 1 SPECIFICATIONS 6 1 WARRANTY PRODUCT RETURN and TECHNICAL ASSISTANCE 7 1 Warranty 7 1 Product Return 7 2 Technical Assistance 7 2 APPENDIX A 8 1 Available Microbor...

Страница 6: ......

Страница 7: ...EX Pump System 1 1 Pump Front Panel 1 2 Pump Rear Panel 1 2 Door Open Occlusion Bed has no Tubing Contact 2 2 Door Closed Automatically Sets Occlusion Bed 2 3 FH10 MICROFLEX Pump System Operating Manual vii Cole Parmer Figures ...

Страница 8: ......

Страница 9: ...commodates one tube at controlled speeds as low as 1 7 rpm Tubing is held in place by spring loaded Tubing Retainers For a list of tubing sizes for use with the Pump System refer to Appendix A Figure 1 1 FH10 MICROFLEX Pump System The self closing Occlusion Bed allows quick loading or changing of tubing The Pump Head rotor contains four rollers for minimum pulsation All units operate from an exter...

Страница 10: ...2 Pump Front Panel The Rear Panel Figure 1 3 contains a DC Power Input jack for connection of primary power and a 4 terminal barrier strip for connection of Remote Start Stop and for a Backup DC supply Figure 1 3 Pump Rear Panel 1 2 FH10 MICROFLEX Pump System Operating Manual Cole Parmer Section 1 Introduction GENERAL DESCRIPTION continued DC Power Input 2 5 mm Coaxial Receptacle Backup DC Input R...

Страница 11: ...rpm Tubing is listed by part number The Pump Head as supplied from the factory is orientated such that the tubing exits the left hand side of the FH10 MICROFLEX Pump System The orientation of the Pump Head can be changed as follows 1 Remove the 4 screws see Figure 2 1 on the face of the unit holding the pump mounting plate in place Retain the 4 screws for reassembly 2 Rotate the Pump Head by turni...

Страница 12: ...ing place the tube onto the rotor allowing the tube to naturally curve around the rotor Insert one side of the tubing into tube retainer by moving the retainer toward the center of the pump and placing tubing in the v notch of the retainer Release the retainer so that the tubing is secured in place Repeat for the other Tubing Retainer The tubing should be stretched slightly around the rollers so t...

Страница 13: ... up the slack see note in Step 5 Connect the external power supply to the applicable input voltage source and the output of the external power supply to the DC input connector on the pump unit NOTE The Power Supply output connection is center positive Terminals 1 and 2 on the rear panel barrier terminal strip Figure 1 3 provide a means for connecting a remote DC power source The positive terminal ...

Страница 14: ...d together by a Shorting Bar For remote control by switch closure remove the Shorting Bar and connect the two terminals of the remote control switch to terminals 3 and 4 A closure of the remote control switch contacts will start the Pump System Opening the contact will stop the Pump System 2 4 FH10 MICROFLEX Pump System Operating Manual Cole Parmer Section 2 Installation and Setup Remote Start Sto...

Страница 15: ...se or a counterclockwise direction The same control used to select direction also turns power on or off Select direction of pump operation desired PWR indicator should light Pump speed is controlled by the variable Speed Control Turning the control clockwise increases the speed Tube life is decreased with increased operating speed The push button is used for priming and purging the Pump System Whe...

Страница 16: ......

Страница 17: ...ole Parmer Section 4 Maintenance DANGER Remove power from the Pump System before any cleaning operation is started Clean exterior surfaces of case control panel and pump rollers using a dry or damp cloth Never immerse nor use excessive fluid Cleaning ...

Страница 18: ......

Страница 19: ...ead Assembly 4 Roller 111005 CR Description Part No Universal Power Supply 100 240V AC 77200 07 Line Cord Australia 50001 60 Line Cord Denmark 50001 62 Line Cord India 50001 64 Line Cord U S Std 115V 50001 68 Line Cord Israel 50001 69 Line Cord Europe 50001 70 Line Cord England 50001 72 Line Cord Switzerland 50001 74 Line Cord Italy 50001 76 Line Cord U S 230V 50001 78 Replacement Parts Accessorie...

Страница 20: ......

Страница 21: ...e Input Supply Voltage Frequency Model 77720 00 77720 02 115V AC nominal 50 60 Hz and 77720 04 90 130V AC 400 mA AC 230V AC nominal 50 60 Hz 190 260V AC 250 mA max Power Input 11 15V DC to terminals 1 and 2 of terminal strip or external power supply Installation Category Model 77720 00 77720 02 Category II per IEC664 and 77720 04 Local level appliances portable equipment etc Remote Start Stop Cont...

Страница 22: ...vel 70 dBa 1 meter Storage Temperature 49 F to 149 F 45 C to 65 C Humidity Non cond 10 to 90 Altitude Less than 6600 ft 2000 m Pollution Degree Pollution Degree 2 per IEC664 Indoor usage lab office Compliance For CE Mark EN61326 1 A2 2001 EMC Directive 2011 65 EU RoHS Directive EN809 EU Machinery Directive Converter is UL cUL listed and CE CCC approved Regulatory agency specifications not applicab...

Страница 23: ...urer s or distributor s most recent catalog This warranty shall not apply to a defects or damage resulting from i misuse of the product ii use of the product in other than its normal and customary manner iii accident or neglect iv improper testing operation maintenance service repair installation or storage v unauthorized alteration or modification or b post expiration dated materials THIS WARRANT...

Страница 24: ... for the return For your protection pack the product carefully and insure it against possible damage or loss Any damages resulting from improper packaging are your responsibility If you have any questions about the use of this product contact the Manufacturer or authorized seller 7 2 FH10 MICROFLEX Pump System Operating Manual Cole Parmer Section 7 Warranty Product Return and Technical Assistance ...

Страница 25: ...lable Dark Gray indicates Special Order check with factory Tubing Suffix Tubing ID in mm PHARMED BPT Silicone Peroxide Silicone Platinum TYGON E Lab TYGON E Food C FLEX TYGON E LFL Solvent Hydrocarbon VITON 95809 07625 95590 06460 06457 95718 06449 95712 97632 10 0 007 0 19 12 0 010 0 25 14 0 015 0 38 16 0 017 0 44 18 0 020 0 51 22 0 025 0 64 24 0 030 0 76 26 0 035 0 89 28 0 040 1 02 30 0 045 1 14...

Страница 26: ... 13 0 100 425 12 0 010 0 25 22 5 180 730 14 0 015 0 38 50 5 400 1650 16 0 017 0 44 67 0 535 2200 18 0 020 0 51 87 0 700 2900 22 0 025 0 64 135 1050 4500 24 0 030 0 76 185 1450 6250 26 0 035 0 89 245 1950 8300 28 0 040 1 02 315 2500 10400 30 0 045 1 14 385 3100 13000 32 0 051 1 30 485 3850 16300 34 0 056 1 42 565 4500 19100 36 0 060 1 52 635 5100 21300 38 0 065 1 65 730 5850 24700 40 0 073 1 85 885...

Страница 27: ......

Страница 28: ...00 MASTERFLEX 1 800 637 3739 Outside US Canada 1 847 549 7600 1 847 381 7050 www masterflex com www coleparmer com E mail techinfo coleparmer com EN809 manufactured by Cole Parmer Instrument Company LLC 28W092 Commercial Avenue Barrington IL 60010 ...

Отзывы: