Cole Parmer 52411-00 Скачать руководство пользователя страница 13

                                                                                                   

52411Dryingoven_ver_1.0

 

www.coleparmer.com

                                                                                                                                                                       

 

7 Clean and maintenance 

1.  Make  sure  to  take  proper  maintenance  and  cleaning  of  the  instrument  to  guarantee  its 

conditions. 

2. The inner chamber of the instrument is made of stainless steel, so it can be cleaned with any 

detergent provided which is not aggressive and/or corrosive.   

3.  User  should  clean  the  inside  and  outside  surfaces  with  a  standard  all-purpose  cleaner 

sprayed on a soft cloth.   

4.  Before  proceeding  with  any  cleaning  or  decontamination,  the  user  must  ensure  that  the 

cleaning method will not damage the instrument.   

 

IMPORTANT

 

If the instrument must be returned for service, it is necessary to provide for proper cleaning 

and possible decontamination for pathogens.   

The original package is recommended for the product if it needs to be sent it in for repairs. If 

the  original  package  is  missing,  it  is  necessary  to  provide  another  proper  cover  pack  for 

transportation.   

Any damage caused from the incorrect shipping will not be covered by warranty.   

 

7.1 Air Change (Forced air series only) 

 

In forced air ovens, there is a knob on the top of the unit to open/close the air flap. Opening the 

air flap on the back of chamber serves to adjust air change. 

 

  If the air flap is open, fresh air comes in via aeration vent. 

 

  If the air flap is completely open, the internal temperature accuracy and stability can be 

negatively influenced. 

 

 

Содержание 52411-00

Страница 1: ...52411Dryingoven_ver_1 0 Forced Air Oven Natural Convection Oven User Manual...

Страница 2: ...sed by failure to follow instructions lack of maintenance and any unauthorized modification 2 Contents of package The instrument is delivered complete with the following parts Drying Oven main unit 2...

Страница 3: ...for connecting to the mains power supply replace the plug with a suitable alternative THIS OPERATION SHOULD ONLY BE UNDERTAKEN BY A QUALIFIED ELECTRICIAN NOTE Refer to the equipment rating plate to en...

Страница 4: ...ng surface when the set temperature is over 176 F 80 C 8 Do not put hands or objects into the air inlet or air outlet 9 Unauthorized repair is not allowed The unit should have routine inspections and...

Страница 5: ...placed on solid surface to keep it horizontal 2 Aggressively opening or closing the door may cause damage to the door oven or injury to users 4 Product introductions 4 1 Function introduction Control...

Страница 6: ...52411Dryingoven_ver_1 0 www coleparmer com 4 2 Display and commands 4 2 1 Display introduction Running status Temperature Set Temperature Fan Status Buzzer MUTE ALARM Timer...

Страница 7: ...change the digit Program units tens etc of the value of the parameter you are editing 3 In combination with the key allows access to menus with password 4 and adjustment buttons allow users to increas...

Страница 8: ...aker 220V 7A 5 x 20 mm glass fast blow 120V 16A Circuit Breaker 220V 10A 5 x 20 mm glass fast blow Interior Dimensions W x D x H 250x260x250mm 340x320x320mm 420x395x350mm 450x400x450mm Model 52411 17...

Страница 9: ...uit breaker Interior Dimensions W x D x H 320x300x355mm 400x330x415mm 450x430x505mm 520x500x575mm 570x560x640mm 5 Temperature Controller Detailed Operation 5 1 Switch on 1 Connect the power according...

Страница 10: ...tion 1 After setting the operating parameters press button for about 4 5 seconds to start the heating cycle cooling process with defined time in hh mm or continue the process for 00 00 When the word E...

Страница 11: ...arts the work cycle but it doesn t immediately heat the word end and the set delay time alternately blink on the top right part of display counting the wait time until the real starting of heating Onc...

Страница 12: ...s Temperature offset on single point After set the Pb value Press to exit 6 2 Other parameters function in Menu Here are the passwords and access sequence to various parameters functions PASSWORD FUNC...

Страница 13: ...he instrument must be returned for service it is necessary to provide for proper cleaning and possible decontamination for pathogens The original package is recommended for the product if it needs to...

Страница 14: ...ing Abnormal temperature display Sensor is out or wiring is broken Repair or replace Pt100 No temperature rise Check if timing is set up and time is up Refer to the operation of timing function The co...

Страница 15: ...tific GmbH Futtererstr 16 97877 Wertheim Deutschland T 49 9377 9203 0 E cde sales antylia com W coleparmer de UK Antylia Scientific 9 Orion Court Abuscade Road Colmworth Business Park St Neots PE19 8Y...