SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

Compressor not running.

Fuse blown or circuit breaker tripped.

Replace fuse or reset circuit 

breaker.

Power cord unplugged.

Plug in power cord.

Thermostat set too high.

Set thermostat to lower 

temperature.

Cabinet in defrost cycle.

Wait for defrost cycle to finish.

Condensing unit runs for

Excessive amount of warm product

Allow adequate time for 

long periods of time.

placed in cabinet.

product to cool down.

Prolonged door opening or door ajar.

Ensure doors are closed when 

not in use.  Avoid opening 

doors for long periods of time.

Door gasket(s) not sealing properly.

Ensure gaskets are snapped in

completely.  Remove gasket 

and wash with soap and water.  

Check condition of gasket and 

replace if necessary.

Dirty condenser coil.

Clean the condenser coil.

Evaporator coil iced over.

Unplug unit and allow coil to 

defrost.  Make sure thermostat 

is not set too cold.  Ensure that 

door gasket(s) are sealing 

properly.

Cabinet temperature is

Thermostat set too warm.

Set thermostat to lower 

too warm.

temperature.

Blocking air flow.

Re-arrange product to allow for

proper air flow.  Make sure 

there is at least four inches of 

clearance from evaporator.

Excessive amount of warm product

Allow adequate time for 

placed in cabinet.

product to cool down.

Fuse blown or circuit breaker tripped.

Replace fuse or reset circuit 

breaker.

Dirty condenser coil.

Clean the condenser coil.

Prolonged door opening or door ajar.

Ensure doors are closed when 

not in use.  Avoid opening 

doors for long periods of time.

Evaporator coil iced over.

(see above)

Cabinet is noisy.

Loose part(s).

Locate and tighten loose 

part(s).

Tubing vibration.

Ensure tubing is free from 

contact with other tubing or 

components.

-7-

Содержание U1BFF-06S

Страница 1: ...igerators Freezers Models U1BRR 06S U1BFF 06S U2BRR 12S U2BFF 12S This manual contains important information regarding your new ColdTech unit Please read the manual thoroughly prior to equipment set up operation and maintenance Failure to comply with regular maintenance guidlines outlined in this manual may void warranty MUST READ COMMERCIAL REFRIGERATOR AND FREEZER OWNER S MANUAL ...

Страница 2: ... ColdTech cabinet 4 Damage to parts due to misuse abuse neglect or accidents 5 Premium labor rates due to holidays overtime travel time mileage etc not specifically authorized by Jimex Corp prior to service 6 Repairs due to modifications to the ColdTech unit or refrigeration system including remoting location of compressor s door hinge reversal etc 7 Claims for indirect or consequential damages in...

Страница 3: ...sed efficiency and damage to the unit 3 Avoid installation in a high humidity and or dusty area humidity could cause unit to rust and decrease effeciency of the unit dust collected on condenser coil will cause unit to malfunction Clean the condenser at least once a month with a brush or clean cloth malfunction due to dirty condenser will void warranty 4 Select a location away from heat and moistur...

Страница 4: ...own time the evaporator fan continues to circulate air through the evaporator coil This air circulation raises the coil temperature above the freezing point melting any accumulated frost Run off water is drained into the evaporator pan and evaporated Freezer coils are defrosted electrically Automatic defrost timers are built in to the refrigeration system and may not be adjusted The defrost timers...

Страница 5: ...use damage to the compressor 1 To minimize shock and fire hazards please do not plug or unplug the cord with wet hands 2 During maintenance and cleaning please unplug the unit 1 To minimize shock and fire hazards make sure that the unit is properly grounded 1 Do not attempt to remove or repair any component unless instructed by factory 2 Make sure that the unit is not resting on or against the ele...

Страница 6: ...o not use steel wool caustic soap abrasive cleaners or bleach that may damage the stainless steel surface Wash door gaskets on a regular basis preferably weekly Simply remove door gasket from the frame of the door soak in warm water and soap for thirty 30 minutes dry with soft cloth and replace Check door gaskets for proper seal after they are replaced Periodically remove the shelves and pilasters...

Страница 7: ...ondenser coil Clean the condenser coil Evaporator coil iced over Unplug unit and allow coil to defrost Make sure thermostat is not set too cold Ensure that door gasket s are sealing properly Cabinet temperature is Thermostat set too warm Set thermostat to lower too warm temperature Blocking air flow Re arrange product to allow for proper air flow Make sure there is at least four inches of clearanc...

Страница 8: ...d procedures are not followed warranty claims will be denied Notice ColdTech reserves the right to make changes in design and specifications without prior notice MODEL _______________________________ SERIAL _______________________________ PURCHASE DATE _______________________ 1575 Zephyr Ave Hayward CA 94544 800 314 4477 510 477 3400 f 510 477 3413 www coldtechUSA com ...

Отзывы: