TEMPERATURE CONTROLS

The temperature controls are factory-set to maintain an average temperature of 38 F in refrigerators and 0 
F in freezers.  To maintain a different temperature, simply adjust the control knob located inside the unit.  
To decrease the temperature (colder), turn clockwise.  To increase the temperature (warmer), turn 
counter-clockwise - 

see diagram

LOADING PRODUCT

Shelves have been factory-installed for your convenience.  Before loading shelves, please be sure that all 
shelf clips are completely fastened in their correct locations.  It is important that all shelves rest completely 
level before stocking your cabinet with product.  
In order to maintain correct air flow inside the unit, please be sure to leave two to four (2 to 4) inches of 
space between the back wall and stored product.  Blocking the evaporator fans will result in a warmer 
cabinet temperature, and ultimately compressor failure.  

DEFROST SYSTEMS

Refrigerator coils are kept below the freezing point (32 F).  During compressor down-time, the evaporator 
fan continues to circulate air through the evaporator coil.  This air circulation raises the coil temperature 
above the freezing point, melting any accumulated frost.  Run-off water is drained into the evaporator pan 
and evaporated.  **Freezer coils are defrosted electrically.**  Automatic defrost timers are built-in to the 
refrigeration system and may not be adjusted.  The defrost timers automatically initiate at pre-set intervals 
and for a pre-determined duration.  

**PLEASE NOTE: Excessive door openings should be avoided in order to maintain cabinet temperature 
and to eliminate the possibility of coil freeze-up.**

LOADING FOOD PANS

Pizza prep units and sandwich prep units are designed to function with all pans in place, even if some 
pans are to be left empty.  For maximum food freshness, fill the pans only with an amount that can be 
used in a specific usage period.  During non-use, please close the insulated lid cover.

 

-4-

CAUTION

Setting the temperature control to the 

coldest setting may cause the evaporator 

coil to freeze and ice up.  This will eventually 

result in a warmer cabinet temperature.

TEMPERATURE

 READING

OFF

1

7

6

5

3

4

2

Temperatures range from 

7 (coldest) to 1 (warmest).  

Содержание U1BFF-06S

Страница 1: ...igerators Freezers Models U1BRR 06S U1BFF 06S U2BRR 12S U2BFF 12S This manual contains important information regarding your new ColdTech unit Please read the manual thoroughly prior to equipment set up operation and maintenance Failure to comply with regular maintenance guidlines outlined in this manual may void warranty MUST READ COMMERCIAL REFRIGERATOR AND FREEZER OWNER S MANUAL ...

Страница 2: ... ColdTech cabinet 4 Damage to parts due to misuse abuse neglect or accidents 5 Premium labor rates due to holidays overtime travel time mileage etc not specifically authorized by Jimex Corp prior to service 6 Repairs due to modifications to the ColdTech unit or refrigeration system including remoting location of compressor s door hinge reversal etc 7 Claims for indirect or consequential damages in...

Страница 3: ...sed efficiency and damage to the unit 3 Avoid installation in a high humidity and or dusty area humidity could cause unit to rust and decrease effeciency of the unit dust collected on condenser coil will cause unit to malfunction Clean the condenser at least once a month with a brush or clean cloth malfunction due to dirty condenser will void warranty 4 Select a location away from heat and moistur...

Страница 4: ...own time the evaporator fan continues to circulate air through the evaporator coil This air circulation raises the coil temperature above the freezing point melting any accumulated frost Run off water is drained into the evaporator pan and evaporated Freezer coils are defrosted electrically Automatic defrost timers are built in to the refrigeration system and may not be adjusted The defrost timers...

Страница 5: ...use damage to the compressor 1 To minimize shock and fire hazards please do not plug or unplug the cord with wet hands 2 During maintenance and cleaning please unplug the unit 1 To minimize shock and fire hazards make sure that the unit is properly grounded 1 Do not attempt to remove or repair any component unless instructed by factory 2 Make sure that the unit is not resting on or against the ele...

Страница 6: ...o not use steel wool caustic soap abrasive cleaners or bleach that may damage the stainless steel surface Wash door gaskets on a regular basis preferably weekly Simply remove door gasket from the frame of the door soak in warm water and soap for thirty 30 minutes dry with soft cloth and replace Check door gaskets for proper seal after they are replaced Periodically remove the shelves and pilasters...

Страница 7: ...ondenser coil Clean the condenser coil Evaporator coil iced over Unplug unit and allow coil to defrost Make sure thermostat is not set too cold Ensure that door gasket s are sealing properly Cabinet temperature is Thermostat set too warm Set thermostat to lower too warm temperature Blocking air flow Re arrange product to allow for proper air flow Make sure there is at least four inches of clearanc...

Страница 8: ...d procedures are not followed warranty claims will be denied Notice ColdTech reserves the right to make changes in design and specifications without prior notice MODEL _______________________________ SERIAL _______________________________ PURCHASE DATE _______________________ 1575 Zephyr Ave Hayward CA 94544 800 314 4477 510 477 3400 f 510 477 3413 www coldtechUSA com ...

Отзывы: