32
Troubleshooting
Problem description
Possible reason and solution
Machine is not
turning on after
pushing ON/OFF
•
Check power supply source
•
Push and release emergency stop, followed by turning the
machine Off and On
For further support, call Customer Service 1-800-777-9101 USA
+32 (0) 1353 9659 Europe
Air is not flowing
Verify compressed air supply is on and at minimum 72 psi / 5
bar or above.
Verify blasting pressure is regulated above 0 psi / bar.
Check signal cable connections
For further support, call Customer Service 1-800-777-9101 USA
+32 (0) 1353 9659 Europe
Dosing unit is not
working / ice is not
flowing
Check ‘Ice On’ LED is on when trigger is pulled, if not:
•
Empty the hopper and check if the dosing disc is spinning
when activating the trigger
•
Check signal cable connections
Check ammeter range is less than 30 or not in the red, if so:
•
Check hopper/dosing disc for foreign objects
•
Dosing disk may be frozen. Call service for thawing
procedures
For further support, call Customer Service 1-800-777-9101 USA
+32 (0) 1353 9659 Europe
Содержание IceTech Evolution Line Xcel 6
Страница 1: ...Manual ENG EL MANUAL Rev A...
Страница 2: ...2 IceTech A S Industrivej 62 DK 6740 Bramming Copyright 2016 by IceTech A S All rights reserved...
Страница 3: ...3 Date Rev Document Description Affected Pages August 16 2016 A SOP All Revision History...
Страница 12: ...12 1 Dry ice hopper 2 Blasting hose connection 3 Electrical box 4 Pneumatic vibrator 5 Dosing system...
Страница 13: ...13 1 Power cable 2 Air filtration unit with regulation 3 Exhaust pipe 4 Flanged connection 5 Transformer...
Страница 15: ...15 LABELS ON THE MACHINE Identification Plate Warning Signs Label...
Страница 36: ...36 IceTech A S Industrivej 62 DK 6740 Bramming Copyright 2016 by IceTech A S All rights reserved...