SHUTTING DOWN THE DRY ICE BLASTING MACHINE
When the cleaning task has been completed, the following procedure must be carried
out before the machine is dismantled or stored:
• Empty the hopper.
• Activate the trigger on the blasting gun for a few seconds in order to empty the system
of possible dry ice residue.
• Close the compressed air supply.
• Activate the trigger on the blasting gun for a few seconds in order to depressurize the
system.
• Turn off the machine (press the ON/OFF button).
• Disconnect the main power supply.
• Bleed the pressure from the air supply lline.
• Disconnect the compressed air supply.
• It is recommended to disconnect the blasting hose.
• Avoid kinking the blasting hose, when rolling it up.
EMERGENCY STOP
Activation of the emergency stop button immediately stops the blasting air stream and
the dry ice flow. Before the machine can be restarted, the following procedure must be
carried out:
• Disengage the emergency stop button (twist and release the button).
• Push the Reset button.
• Restart the blasting air stream by activating the trigger switch on the blasting gun.
CORRECT ORDER IS IMPORTANT!
FIRST disconnect the signal cable – THEN the blasting hose
couplings!!
Содержание IceTech Evolution Line Xcel 6
Страница 1: ...Manual ENG EL MANUAL Rev A...
Страница 2: ...2 IceTech A S Industrivej 62 DK 6740 Bramming Copyright 2016 by IceTech A S All rights reserved...
Страница 3: ...3 Date Rev Document Description Affected Pages August 16 2016 A SOP All Revision History...
Страница 12: ...12 1 Dry ice hopper 2 Blasting hose connection 3 Electrical box 4 Pneumatic vibrator 5 Dosing system...
Страница 13: ...13 1 Power cable 2 Air filtration unit with regulation 3 Exhaust pipe 4 Flanged connection 5 Transformer...
Страница 15: ...15 LABELS ON THE MACHINE Identification Plate Warning Signs Label...
Страница 36: ...36 IceTech A S Industrivej 62 DK 6740 Bramming Copyright 2016 by IceTech A S All rights reserved...