TECHNICAL DATA
Rated Output of Dry Ice:
kg/h: up to 120
lbs/h: up to 264,5
Depending on nozzle combination.
Inlet Liquid CO
2
Pressure:
Liquid CO2 Supply System
COMBI PCS 110 DUAL
Supply Pressure (Min-Max)
13-18 bar (189-261 psi)
Supply Pressure Range
+/- 1.0 bar (14.5 psi)
Supply Pressure (Recommended PBU Setting)
16,5 bar (240 psi)
Liquid CO
2
Dryness Fraction:
The water content should not exceed 35 ppm and should not be less than 5 ppm – or equivalent to a dew point
temperature of -66°C to -51°C (-86.8°F to -59.8°F).
NOTE:
The liquid CO
2
supply must be completely free of oil and must have a minimal purity of 99.9%.
Liquid CO
2
Supply Pipe:
Internal dia. 20 mm (0.8 inch), very well insulated with a minimum number of bends and fittings.
NOTE:
If over 20 m (65.6 feet) in length, use an internal dia. of 25 mm (1 inch).
Power Supply:
3 x 380-480 V AC + PE, 50-60Hz,
TN-S Earthing system
Imax. 32 A
Air Supply:
Bar:
min. 5 – max. 10
Psi:
min 72 - 145
Rated Power:
15 kW / 20 Hp @3 x 400V AC
Rated Air Consumption:
Nm
3
/min: 3-11
Cfm: 106-388
Depending on nozzle combination.
Machine Dimensions:
Length: 1800 mm / 71 in
Width: 1200 mm / 47.3 in
Height: 2100 mm / 82.7 in
Height: 2200mm / 82.7 in (incl. ext. legs and pipes)
Weight: 1380kg / 3042 lbs
Noise level:
below 75 dB(a)
COMBI PCS 110 DUAL
Operator’s Manual
Version:
1.0
Page:
10 of 28
Date:
10.05.2021
Содержание 2A0388
Страница 1: ......
Страница 5: ...COMBI PCS 110 DUAL Operator s Manual Version 1 0 Page 4 of 28 Date 10 05 2021...
Страница 26: ...Notes COMBI PCS 110 DUAL Operator s Manual Version 1 0 Page 25 of 28 Date 10 05 2021...
Страница 27: ...COMBI PCS 110 DUAL Operator s Manual Version 1 0 Page 26 of 28 Date 10 05 2021...