12 | Repair
72 / 88
Operating instructions CMVpro 125-400 ATEX | Version 1-en
• Inspect sealing ring of the inlet cover for damage prior to installation and re-
place if necessary.
• Tighten the fastening screws of the inlet cover according to the table:
Fan/size
Fastener threads
Max. tightening torque
[Nm]
CMVpro 125
M6
2
CMVpro 160 - 400
M8
5
• Conduct a test run after repair
_
57].
12.6
Casing exchange
Conditions:
• Fan has been prepared for repairs
_
69].
• Impeller has been removed
_
Procedure:
• Disconnect grounding cable
from casing
_
• Loosen and remove fasten-
ing screws and correspond-
ing wedge-lock washers
(Nord-Lock, see detail) from
the back of the support.
• Remove casing from sup-
port.
Fig. 38:
Removing casing
Mounting instructions
• Reinstall hub seal (option)
_
76].
• Align casing opening to the center of the motor shaft.
•
NOTICE
Secure the fastening screws of the casing
• with wedge-lock washers (mandatory; Nord-Lock, see detail). Do not
use threadlocker (Loctite)!
• to the tightening torque specified in the following table.
Fan/size
Fastener threads
Max. tightening torque
[Nm]
CMVpro 125
M6
2
CMVpro 160 - 400
M8
5
• Tighten the grounding cable to the ground connection of the casing
_