12 | Repair
76 / 88
Operating instructions CMVpro 125-400 ATEX | Version 1-en
12.9
Hub seal (option) replacement
Conditions:
• Impeller has been removed
_
70].
Procedure:
1.
Remove hub seal from seal
casing using tweezers (see
detail).
2.
Lubricate new hub seal:
Saturate bearing surface of
motor shaft with Teflon
spray.
3.
Insert new hub seal in seal
casing.
• Order the hub seal as a
wear part in a timely
manner.
4.
Assemble fan
_
70], mount-
ing instructions.
Fig. 41:
Inserting hub seal