Coin Enable
Coin Enable allows the user to select which coins are and are not accepted within the standard coin
set for the country.
See Figure 49 for enabling and disabling acceptance of coins within the standard coin set.
The standard coin set for the country is determined by the changer “Country Code”. See the
Guardian Naming Convention (page 5) to determine the Country Code of the changer.
SECTION 5: ADVANCED CONFIGURATION
Coin Enable / Coin Security Level
Coin Enable / Coin Security Level
C O IN C O N F IG
C oin E nable
▲
▼
C O IN C O N F IG
C hange M gm t
▲
▼
C O IN C O N F IG
S ecurity Level
S E T U P
C oin C onfig
▲
▼
Enter
▲
▼
Scroll
▲
▼
Scroll
S elect C oins to
E
nable /
D
isable
U S 25¢E U S $1 D
U S 5¢ E U S 10¢E
T o A ccept A ll
P ress E N T E R
Enter
◄ ►
S elect C oin;
▲▼
D isable C oin
1. P ush
MENU
button.
2. S croll using arrow keys to screen below
Changer
Steady State
Mode
Enter
Loop
Loop
▲
▼
Scroll
D isp la y sho w s current
status for each coin.
Enter
S ecurity Level
H
igh /
S
tandard
U S 25¢H U S $1 H
U S 5¢ S U S 10¢S
T o A ccept A ll
P ress E N T E R
◄ ►
S elect C oin;
▲▼
S ecurity Lvl
Loop
Loop
D isp la y sho w s current
security setting for each coin.
Enter
Guardian E6 Hint
Guardian E6 Hint
This feature is available on Guardian E6 by
using the Coinco FP-5 Field Programmer.
Coin Enable / Coin Security Level
Coin Enable / Coin Security Level
C O IN C O N F IG
C oin E nable
▲
▼
C O IN C O N F IG
C hange M gm t
▲
▼
C O IN C O N F IG
S ecurity Level
S E T U P
C oin C onfig
▲
▼
Enter
▲
▼
Scroll
▲
▼
Scroll
▲
▼
Scroll
▲
▼
Scroll
S elect C oins to
E
nable /
D
isable
U S 25¢E U S $1 D
U S 5¢ E U S 10¢E
T o A ccept A ll
P ress E N T E R
Enter
◄ ►
S elect C oin;
▲▼
D isable C oin
1. P ush
MENU
button.
2. S croll using arrow keys to screen below
Changer
Steady State
Mode
Enter
Loop
Loop
Loop
Loop
▲
▼
Scroll
▲
▼
Scroll
D isp la y sho w s current
status for each coin.
Enter
S ecurity Level
H
igh /
S
tandard
U S 25¢H U S $1 H
U S 5¢ S U S 10¢S
T o A ccept A ll
P ress E N T E R
◄ ►
S elect C oin;
▲▼
S ecurity Lvl
Loop
Loop
Loop
Loop
D isp la y sho w s current
security setting for each coin.
Enter
Guardian E6 Hint
Guardian E6 Hint
This feature is available on Guardian E6 by
using the Coinco FP-5 Field Programmer.
Figure 49
Coin Security Level
Allows the user to determine how tight the acceptance rate should be for each type of accepted coin.
The Guardian Series changers feature two levels of security:
1.
Standard Security
(default setting): accepts a coin at a minimum of
95%
at normal
temperatures and changer installation tilts; extreme conditions are
90%
.
•
High Security
: is
90%
and
80%
respectively.
See Figure 49 for how to change the security level for each accepted coin.
Increasing the Coin Security Level above level 5 will make it less likely that a similar slug will
be accepted, yet it will also reject a higher percentage of authentic coins. It is recommended
that security settings 6-9 only be used in specifi c instances to deal with higher slug rates.