3 SPECIFICATIONS
3.7 Cable Specifications
25
3
3.7
Cable Specifications
This section shows the specifications of an Ethernet cable (COGNEX product) and breakout cable (COGNEX product) to be
connected to a code reader CF26.
Ethernet cables (COGNEX product) and breakout cables (COGNEX product) are sold separately.
Ethernet cable (COGNEX product)
Ethernet cables (COGNEX product) are used for directly connecting a code reader CF26 to one device, or connecting a code
reader to multiple devices via a switching hub or a router.
CCB-84901-2001-**
If the bend radius or service loop is smaller than 10 times of the cable diameter, the Ethernet cable (COGNEX
product) may cause cable shielding degradation, cable damage, or wear out in a short period.
The bend radius must be at least 152.4 mm from the connector.
P1: To a code reader
P1