Use the Accessory Wall Mounting Brackets
The accessory wall mounting bracket kit (BKT-WALL-VC200-01) includes two wall mounting brackets and M4 screws
(quantity 4) to secure the controller to a mounting surface.
CAUTION
:
l
The vision controller must be mounted in a vertical orientation with the top of the controller up, and cannot
be mounted in a horizontal orientation.
l
To ensure sufficient ventilation, the vision controller must be mounted with sufficient clearance. If mounting
to the bottom surface, 50mm of clearance is required above and on both sides of the vision controller. If
mounting to the back surface or using the accessory wall mounting bracket or DIN rail mounting bracket,
24.5mm of clearance is required above, below and on both sides of the vision controller. If an adjacent
device also produces heat, additional space or cooling is required if air space around the vision controller
exceeds 45°C (113°F).
l
Allow sufficient clearance and strain relief for wires and cables connected to the vision controller.
1. Align the holes on the wall mounting brackets with the mounting holes on the vision controller. The vision
controller mounting hole screw thread is M4 x 0.7.
2. Insert the M4 screws into the mounting holes and tighten the screws using a 3mm hex wrench; the maximum
torque is 2 Nm (18 in-lb).