Multifunction Port
The following information pertains to connecting power via the multifunction port, an M12-12 port with female pins.
The shielded Multifunction cable (CCB-2901868-05) is recommended. It uses an M12-12 connector with male pins,
providing access to trigger and inputs.
Pin #
Signal Name
Notes
Wire Color
9
PWR
+ 11 VDC - 30V DC (rated value 24 V);
max. 500 mA
1
Red
2
GND
0 V
Blue
3
+Laser on/off
Optional
White
1
-Laser on/off
Brown
6
In1
Digital Input 1
Yellow
4
GND-In1
Ground In1
Green
5
In2
Digital Input 2
Pink
8
GND-In2
Ground In2
Gray
10
In3
Digital Input 3
Purple
7
GND-In3
Ground In3
Black
l
PWR, GND
: galvanically isolated from In1, In2, In3, and Laser on/off
l
Laser on/off
: Input galvanically isolated from GND, In1, In2, In3
l
In1, In2, In3
: Inputs galvanically isolated from GND and Laser on/off
l
GND-In1, GND-In2, GND-In3 - IO ground references for In1, In2, In3. Galvanically isolated from GND.
Note
: If the sensor is connected to a network adapter/switch that is capable of PoE and if you also use the power
supply of the multifunction port, these two power supplies have to be galvanically isolated.
1
The operating voltage is protected against reverse polarity.
23
Installation Instructions
Содержание DS900 Series
Страница 1: ...DS900 Series Displacement Sensors Reference 02 21 2018 Version 9 3 0 5...
Страница 14: ...Dimensions DS910B 14 Dimensions DS910B...
Страница 17: ...Dimensions DS925B 17 Dimensions DS925B...
Страница 18: ...18 Dimensions DS925B...
Страница 28: ...28 RS422 Synchronization...
Страница 31: ...31 Measuring Field Selection...
Страница 42: ...January 2018...