5. Go to the Displayed Image Settings pane and change the Images to Use according to what you want to see on
Live Display: the original or the filtered image.
6. You can compare the original and filtered results on the Results Display if you choose the images from the Read
Result History.
The example images were taken using the Equalize filter.
Package Detection Support
You can connect your package detection sensor to one of the digital inputs of your DataMan reader. When the reader
receives a signal that a package is detected, images that the reader collected are not discarded at the end of the trigger.
This way you can make sure that there was a package there, only the code was not readable. Looking at the No Read
images will help you find out why there were no decode results.
Package detection is only supported with Continuous trigger mode.
To make sure that the No Read images are collected, perform the following:
1. Connect your package detection device to one of the Inputs of your reader.
2. On the
Inputs/Outputs
pane, check
Allow Buffered No-Read Images
on the input you connected your reader to.
3. On the
Inputs/Outputs
pane, click
Buffering and Transfer
, and in the
Image Buffering
pane, change
What
Results to Buffer
under Buffering Settings to All, or No Read.
l
In the case of
All
, good reads are also saved together with No Reads.
l
In the case of
No Read
, the image is buffered if the reader fails to read.
For more information, see the
DataMan Fixed-Mount Readers Reference
, available through the Windows
Start
menu
or the DataMan Setup Tool
Help
menu.
DataMan 370 Series Multi-Reader Sync Option
For trigger modes other than
Presentation
, the DataMan 370 supports multi-reader trigger synchronization, also known
as Multi-Reader Sync. In this option, you configure multiple DataMan readers as a group. Whenever any reader in the
group is triggered, all the readers are triggered and the results from all the readers are assembled and transmitted by a
single reader that you designate as the Primary Reader.
Multi-Reader Sync is used to support extended field of view reading and reading codes from multiple product surfaces:
To configure Multi-Reader Sync, go to the group editor in the DataMan Setup Tool. For more information, see the
Setup
Tool Reference Manual
.
62
Using Your DataMan 370 Reader