Note
: Connectors without a cable should be covered by a protective cap to meet the IP requirements.
This I/O module has an M12x8 X-coded connector for the Ethernet signals and a (male) M12x12 connector for power, I/O
and RS-232.
The signals on the M12x12 connector are the following:
PIN
Signal: 24 VDC Ethernet Model
Signal: PoE Ethernet Model
1
OUT_2
OUT_2
2
TXD
TXD
3
RXD
RXD
4
OUT_3
OUT_3
5
IN_1
IN_1
6
IN_COM
IN_COM
7
+24V VIN
N.C.
8
GND
RS232GND
9
OUT_COM
OUT_COM
10
IN_0
IN_0
11
OUT_0
OUT_0
12
OUT_1
OUT_1
Note
: When angled cables are mounted, all of them point downwards or, in the case of the 90° configuration,
backwards.
Reader Layout
The following images show the built-in lighting system and other features of the DataMan 260.
1
Illumination LEDs
2
LED aimers
3-4*
Mounting holes (M3 x 3.5mm)
5
Trigger button
6
Power indicator
7
Train status indicator
12
Getting Started