External Triggering and Trigger Modes
If you are using external triggering, you can use any of the following methods to trigger your DataMan 150 reader:
1. Press the Trigger button (
) on the reader.
2. Send a pulse on Input-0 line.
3. Send a serial trigger command over the serial line. (You must use RS-232 or USB communications type.)
4. Click the Trigger button (
) or press
<Ctrl>-T
in DataMan Setup Tool.
DataMan 150 supports a variety of trigger modes:
l
Single
: Acquires a single image and attempts to decode any symbol it contains or more than one symbol in cases
where multicode is enabled. The reader relies on an external trigger source.
l
Presentation
: Repeatedly scans for a symbol and decodes it whenever one is detected. The reader relies on an
internal timing mechanism to acquire images.
l
Manual
(default): Begins acquiring images when you press the trigger button on the reader or the discrete trigger
input is activated, and continues acquiring images until a symbol is found and decoded or you release the button
or the discrete trigger input is deactivated.
l
Burst
: Performs multiple image acquisitions based on an external trigger and decodes one or multiple symbols
appearing in the sequence of images.
l
Self
: Similar to
Presentation
mode in that the reader perpetually scans for symbols and decodes them each time
one is detected. Unlike
Presentation
mode, however,
Self
mode supports multicode results and a decode attempt
occurs with every image. The main difference between
Self
and
Presentation
is the fixed and exact interval for
image acquisitions in
Self
.
l
Continuous
: Begins acquiring images based on a single external trigger and continues to acquire images until a
symbol is found and decoded, or until multiple images containing as many codes as specified in multicode mode
are located, or until the trigger is released.
S models do not have Burst and Continuous trigger types.
Training and Trigger Modes
Training is supported for the following trigger modes:
l
Single trigger
l
Burst mode
l
Self trigger
l
Continuous mode
49
Using Your DataMan 150
Содержание DataMan 150 QL
Страница 1: ...DataMan 150 Series Reference Manual 2021May26 Revision 6 1 10 SR1 4...
Страница 40: ...Digital Input Wiring Diagrams Current Sink Configuration Current Source Configuration PNP Configuration 40...
Страница 42: ...Sinking Outputs Sinking Inputs 42...
Страница 56: ......
Страница 57: ...Copyright 2021 Cognex Corporation All Rights Reserved...