Specification
3D-A5005
3D-A5030
3D-A5060
Resolution
X, Y = 42 - 44 µm
X, Y = 195 - 199 µm
X, Y = 361 - 454
µm
Clearance Distance (mm)
The minimum distance required before the
sensor will detect 3D features.
300
1465
1400
Near Field of View (mm x mm)
The size of the area closest to the sensor where
3D features can be detected. Features above
the Near Field of View will not be captured by
the sensor.
60 x 44
280 x 210
520 x 390
Measurement Range (mm)
The total distance in which the sensor can
detect 3D features.
12
80
400
Far Field of View (mm x mm)
The size of the area farthest from the sensor
where 3D features can be detected. Features
below the Far Field of View will not be captured
by the sensor.
65 x 46
285 x 215
645 x 490
Refer to the following diagram for physical dimensions of the 3D-A5000 sensor: