ORIGINAL LINE A
23
FAULT
POSSIBLE SOLUTION
Power switch does not lit
Check plug connection to wall socket.
Check fuse in plug.
Check if hot plate becomes warm, if so
replace power switch.
Hot plate does not become
warm although switch is lit.
Check connection to hot plate.
If hot plate is defective, replace.
Brewer excess steam.
Machine may require descaling.
Spray nozzel may need unblocking.
Hose may be bent.
Inlet to boiler may be blocked. Descale
machine - if boiler still defective - replace.
Machine will not brew.
Check overheating protection.
Check microswicth.
Check connection to boiler.
Boiler unit may need replacing.
The machine does not take
in water
Make sure water tap is open.
Make sure the water hose is not bent.
Check inlet valve.
Check that the display is blinking.
The machines does not
stop taking in water.
Dirt in the inlet valve.
inlet valve is defective - replace
PCB is defective - replace
The machine is giving
wrong amount of water.
Check water tap.
Water hose is bent.
Dirt in inlet valve.
Water amount adjustment set in display is
adjusted faulty. Adjust according to page 21.
Defect floatregulator in inlet valve - replace
A-2
DIMENSION
A
D
E
B
C
F
Model
A
B
C
D
E
F
A-2
595mm
205mm
410mm
428mm
578mm
360mm
Содержание ORIGINAL LINE A
Страница 1: ...ORIGINAL LINE A USER MANUAL UM_EN Part No 1764024_01 Machines with automatic water filling ...
Страница 23: ...ORIGINAL LINE A 23 A 2 DIMENSION A D E B C F Model A B C D E F A 2 595mm 205mm 410mm 428mm 578mm 360mm ...
Страница 24: ...ORIGINAL LINE A 24 DA 4 DIMENSION Model A B C D E F DA 4 410mm 410mm 428mm 595mm 578mm 360mm D C A E B F ...
Страница 25: ...ORIGINAL LINE A 25 Thermos A DIMENSION Model A B C D F Thermos A 557mm 205mm 410mm 708mm 360mm B A F D C ...
Страница 26: ...ORIGINAL LINE A 26 Mega Gold A DIMENSION Model A B C D E Mega Gold A 655mm 205mm 445mm 390mm 806mm A E B D C ...