9.
7. Programming.
1.
Programming automatic controls for manual water filling.
1.1.
Fill the water to
A
in the tank up to the long sensor pin.
See fig. 1
. Approximately 4 litres.
1.2.
Keep button (
B
) pressed and switch on the machine
with the switch (
D
) at the same time.
A
fig.1.
fig.2.
B
C
D
1.3.
The display shows T1
Change the type of machine with buttons
B
or
C
.
1.4.
T1 = HVA automat
T2 = HVM manual
1.5.
Confirm the choice by holding down the buttons (
B
) and (
C
) at the same time
for approximately 5 seconds.
NOTE
Install the plug supplied in the inlet valve (E) to avoid possible leakage.
E