23
BRILLIANCE 3.0
CLEANING AND CARE
Grinder
Every month
Approximately every month the grinder housing and spout should be inspected
for coffee residues and obvious damages.
Proceed as follows:
Fig.1
Fig.2
A
Remove bean container. Remove all coffee residues from the spout and the
grinder housing by grinding through all coffee beans and using a vacuum cleaner
to remove all residues.
Remove the four phillips screws (A, see fig.1) on the top of grinder housing lid.
Carefully detach the grinding housing. Fig.1
Note: its position for correct reassembly. Do not alter the adjustment of
the grinding discs.
Clean the inside of the grinder housing with a soft brush. (See fig.2)
When reassembling the grinder housing, again check for the correct position and
do not alter the grind adjustment of the discs. Fasten the four phillips screws.
Содержание BRILLIANCE 3.0
Страница 1: ...TM_EN Part No 1764040_03 BRILLIANCE 3 0 TECHNICAL MANUAL ...
Страница 37: ...37 BRILLIANCE 3 0 ELECTRICAL DIAGRAM IO Board outputs ...
Страница 38: ...38 BRILLIANCE 3 0 ELECTRICAL DIAGRAM Wiring sketch X 2 capacitor FA2 H8 ...
Страница 40: ...40 BRILLIANCE 3 0 Water system rotary pump FLOW CHARTS ...
Страница 45: ...45 BRILLIANCE 3 0 EXPLODEDVIEW Door Front Drawing 1 9 3 13 12 8 6 10 5 2 15 7 11 4 14 ...
Страница 49: ...49 BRILLIANCE 3 0 Boiler assembly EXPLODEDVIEW Drawing 16 17 18 6 1 11 7 8 9 4 10 15 5 2 13 14 ...
Страница 52: ...52 BRILLIANCE 3 0 EXPLODEDVIEW Canister Drawing 8 1 9 2 3 4 5 6 7 11 10 8 8 8 8 8 8 8 8 8 8 8 8 8 8 ...
Страница 54: ...54 BRILLIANCE 3 0 EXPLODEDVIEW Espresso group Drawing 09 08 07 10 01 14 15 04 05 03 12 13 11 02 06 ...