. Powering up
5.2
Connection to mains power
Mains cable characteristics
The mains cable provided is thermally resistant, complying to the most recent International standards.
Note:
in case of cable replacement, similar cable with comparable thermal resistant qualities must be used ex-
clusively (cable 3 X 1,5 ø external 10 mm, rated 300/500 V, tested to 2 KV, operating temperature -40°C +
180°C, Coemar cod. CV5311).
Connection to mains power
SunLite LED Series
is equipped with an internal cable without power plug.
The max absorption of
SunLite LED Series
is reported in the following table:
- 230V - 1.0A constant during normal exercise.
- 115V - 2.0A constant during normal exercise.
5.1
Operating voltage and frequency
The unit may operates at voltages ranges from 100V to 277V at a frequency of 50 or 60 Hz. It is not needed
to effect any setup procedures:
SunLite LED Series
will automatically adjust its operation to suit any frequency
or voltage within this range.
Power supply protections:
Over current
(Constant current limiting, recovers automatically after fault condition
is removed),
Short circuit
(Hiccup mode, recovers automatically after fault condition is removed),
Over Voltage
(Shut down and latch off o/p voltage, re-power on to recover).
line
neutral
brown
ground
blue
yellow/green