Congratulations on having purchased a new
coemar
product. You have ensured yourself of a fix-
ture of the highest quality, both in the components and in the technology used. We renew our
request for you to complete the service information. This information will assist in prompt and
accurate advice from your
coemar service centre
(in case of problems encountered either
during or subsequent to installation).
1. Packaging
Following the instructions contained in this manual will ensure
the maximum efficiency of this product for years to come.
Open the packaging and ensure that no part of the equipment
has suffered damage in transit. In case of damage to the equip-
ment, contact the carrier immediately by telephone or fax, fol-
lowing this with formal notification in writing.
packing list
Ensure that the packaging contains the following items:
1
sequenza 500 al (complete with safety glass)
1
colour frame
1
“L”-shaped yoke
1
graduated fixing plate, complete with bolts and T-
handle
2. Lamp: Installation
lamp type
and maintenance
sequenza 500 al
uses a linear halogen lamp of either 300 or
500W
The following lamps are available through the
coemar
distribu-
tor network:
coemar cod. 105008
power 300 w
voltage 240 v
luminous flux 5.000 lm
colour temperature 3000° K
base R7s
coemar cod. 105009
power 500 w
voltage 240 v
luminous flux 9.500 lm
colour temperature 3050° K
base R7s
safety
The fixture’s internal temperature can reach 180° C after 5 minu-
tes of operation, with a maximum peak of 200° C; ensure the
lamp is cold prior to attempting removal. The fixture should be
allowed to stand and cool for 10 minutes prior to opening for
lamp replacement or internal inspection.
lamp handling
The lamp is quartz glass and must be handled with care. Follow
the instructions included in the lamp’s packaging. Do not touch
the glass directly, use the tissue provided in the lamp box.
Attention
Disconnect mains power before opening internals