14
5
. Powering up
5.2
Connection to mains power
Mains cable characteristics
The mains cable provided is thermally resistant, complying to the most recent International
standards.
Note:
in case of cable replacement, similar cable with comparable thermal resistant qualities
must be used exclusively (cable 3 X 1,5 ø external 10 mm, rated 300/500V, tested to 2 KV,
operating temperature -40°C + 180°C, Coemar cod. CV5311).
Connection to mains power
LEDko EXT
is equipped with an internal cable without power plug.
The max absorption of
LEDko EXT
is reported in the following table:
- 230 V 0.96 A constant during normal exercise.
- 115 V 1.92 A constant during normal exercise.
5.1
Operating voltage and frequency
The unit may operates at voltages ranges from 85 to 264 V at a frequency of 50 or 60 Hz. It is
not needed to effect any setup procedures:
LEDko EXT
will automatically adjust its operation
to suit any frequency or voltage within this range.