English
Should your DMX 512 controller utilise only XLR 5 sockets, the polarity of pins 1, 2 and 3 must be preserved as shown in the dia-
gram. Do not connect pins 4 and 5.
pin 1= screening 0 volt
pin 4= not connected
pin 2= data –
pin 5= not connected
pin 3= data +
Ensure that all data conductors are isolated from one another and the metal housing of the connector.
Note: the housing of the cannon XLR 3 must be isolated.
3
2
1
Controller
Standard
DMX 512
OUT
Ad altri
Prospot LX
Connect to other
Prospot LX
out
in
out
in