The diagram below indicates some possible problems and solutions if they should occur.
Problem
Possible solution
Par Lite Led IP
won’t turn on.
Mains power is not available to the
Par Lite Led IP
:
- Check that the green Led is on, if so check the incoming voltage to the
Par Lite Led IP.
- Check the main pcb fuse
and that of the switching powersupply.
Par Lite Led IP
doesn’t respond to DMX signal
Incoming DMX may not be being received by the
Par Lite Led IP
:
- check that the led indicating DMX input is flashing. If not, check the
DMX console’s output and any cabling for continuity
.
- Check the dip-switch panel to ensure that no functions are selected
which inhibit
DMX control.
- Par Lite Led IP
may be incorrectly addressed. Check the DMX
addressing.
The
Par Lite Led IP
is set to auto but is not running any
programs
In addtion to setting the AUTO dip-switch to on, it is necessary to also
select
a program number
(see section
9. AUTO function
).
- Multiple programs have been selected - only one program at a time
may be selected.
- Check that amongst the interconnected fixtures, only one has bee set
to Master.
- Ensure that there is no incoming
DMX
signal (this may cause a con-
flict in signals).
16. Frequently asked questions
22
English