5.1. Operating voltage and frequency
The fixture may operate at voltages ranging from 90 to 250V AC at a frequency of 50 or 60 Hz.
It is not necessary to effect any setup procedures, Par Lite Led IP
will automatically adjust its operation to suit any
frequency or voltage within this range.
5.2. Mains connection
Cabling
The mains cable provided is a neoprene type HQ7RN-F suitable for outdoor applications and complying to the most recent international
standards: CEI 20-19, UNEL 35364, CENELEC HD 22.
N.B.
In case of cable replacement, similar cable with comparable qualities must be used exclusively (cable 3x1.5 ø external 10 mm, rated
450/750V, operating temperature -25° +60°.
Connection to mains power
for connection purposes, ensure you plug is of a suitable rating:
•230/240V
0.2 amps constant current.
•208V
0.25 amps constant current.
•100/115V
0.5 amps constant current.
Locate the mains cable which exits the base of the unit and connect as shown below:
ATTENTION!!
• The use of a thermal/magnetic circuit breaker for each fixture is recommended. Strict adherence to regulatory norms
is strongly recommended.
• Par Lite Led IP should not be powered through a Dimmer as this may damage the internal switching powersupply.
• Prior to connecting the device to mains power, ensure that the mains characteristics are within the recommended
range for use with the Par Lite Led IP.
• A good earth connection is essential for the correcdt operation of the Par Lite Led IP. Never install the unit unless the
yellow/gree earth cable is securely connected.
• All cabling and connections should be carried out by suitably qualified personnel.
ground
neutral
live
brown
blue
yellow/green
main