The two leds on the dip-switch panel indicate the functionality of the
Par Lite Led IP
.
A thermal sensor in the body of the
Par Lite Led IP
protects the fixture against overheating. The sensor operates by removing power
to the leds should the operating temperature exceed the factory preset.
Whilst every possible precaution has been taken to ensure the trouble-free operation of your
Par Lite Led IP
, the following periodic
maintenance is highly recommended. We recommend that the voltage to the unit be removed prior to any maintenance procedure tak-
ing place.
14.1. Fuse replacement
Use a multimeter to check the fuse, replacing any faulty or damaged fuses with ones of equal value, dimensions and characteristics.
The following diagram indicates the positioning and characteristics of the protection fuses in the fixture.
Fuse A:
2A F 250V
Fuse B:
4A T 250V
14.2. Periodic maintenance
Mechanicals
Check that the units is not mechanically damaged. Regularly clean the glass by using a soft cloth with a specific cleaning liquid. Check
the sealing to ensure resistance to water and dust and, if necessary, replace the damaged parts.
Electrical components
Check all electrical components for correct earthing, oxidation and proper attachment of all connectors, cleaning and refastening if nec-
essary.
All the components of the
Par Lite Led IP
are available as spare parts from your
Coemar service centre
.
Accurate description of the fixture, model number, and type will assist us in providing for your requirements in an efficient and effective
manner.
15. Spare parts
ATTENTION!!
Always remove mains power prior to opening up the fixture!
14. Maintenance
13. Thermal protection
Led
Function
Led on
Led off
Led flashing
Green
Power
Present
Absent
Undefined
Yellow
DMX state
DMX poorly
connected
No DMX signal
DMX OK
12. Switch panel signal
21
English