safety chains
The use of a safety chain fixed to the unit and to the primary suspension structu-
re is highly recommended to protect against the accidental failure, however
unlikely, of the primary suspension points.
If using an after-market safety chain not manufactured by
coemar
, ensure that it
is of a sufficient rating to hold the weight of the unit.
The safety chain is attached by means of the two holes
B
located in the base of
the unit as shown in the diagram.
protection against liquids
The projector contains electric and electronic components that must not come into contact with water, oil, or any liquid.
movement
The projector has an articulated movement of 360° in the base and 210° through its yoke;
DO NOT
obstruct the articulated
movement in any way.
risk of fire
Each fixture produces heat and must be installed in a well-ventilated position. The minimum recommended distance from flam-
mable material is: 0.5m. Minimum distance from the object being illuminated is: 2m.
forced ventilation
You will note that the projector contains several cooling fans and vents located in the base and the yoke. Under no circumstan-
ces should these be obstructed.
Obstruction of any of these points will result in the over-heating of the unit, detrimentally and seriously affecting the proper ope-
ration of the fixture.
ambient temperature
Never install the projector in locations where there is insufficient flow of circulating air; the ambient temperature should not
exceed 35°C.
preparing the cable
The mains cable provided is thermally resistant, having VDE approval and complying to the most recent international standards, namely
IEC 331, IEC 332 3C,CEI 20 35.
NB:
In case of cable replacement, similar cable with comparable thermal resistant qualities must be used exclusively (cable
3x1,5 ø external 10 mm, rated 300/500V, tested to 2KV, operating temperature -40° +180°,
coemar
cod. CV5309).
mains connection
Fiera
1200
may operate at 208V-230V-240V at 50 or 60Hz (operating voltage and frequency should be selected as discus-
sed in section 5 of this manual).
Prior to connecting the unit to your mains supply, ensure that the model in your possession correctly matches the mains supply
available to you.
For connection purposes, ensure that your plug is of a suitable rating: 9 amps.
Locate the mains cable which exits the base of the unit and connect as shown below:
protection
The use of a thermal magnetic circuit breaker is recommended for each
Fiera
1200
.
A good earth connection is essential for the correct operation of the fixture. Strict adherence to regulatory norms is strongly
recommended.
massa/ground
neutro/neutral
fase/live
marrone - brown
blu - blue
giallo/verde - yellow/green
alimentazione
main
7. Mains connection
B
30
English