Fiera
1200
utilises a Philips 1200 MSD, Philips 1200 MSR or MSR/2 1200W lamp with a G 22 lampbase.
The lamp is available from your
coemar
service centre:
The fixture’s internal temperature can reach 250° C after 5 minutes with a maximum peak of 350° C; ensure that the lamp is
cold prior to attempting removal. The fixture should be allowed to stand and cool for 10 minutes prior to its removal.
Both MSR and MSD lamps are part of the mercury vapour family of discharge lamps and must be handled with great care. The
lamps operate at high pressure, and the slight risk of explosion exists if operated over their recommended lamp life.
We recommend, therefore, that the lamp be replaced within the manufacturer’s specified lamp life.
installing the lamp
1) Using a Philips head screwdriver, loosen the 2 screws which affix the lamp assembly, located at the rear of the projector.
2) Remove the lamp assembly
Attention
Disconnect mains prior to opening up the unit.
Philips 1200 MSD
coemar cod.
105811
power
1200 w
luminous flux
92.000 lm
colour temperature
6.000° K
base
G 22
approximate lamp life
3.000 hours
Philips 1200 MSR
coemar cod.
105090
power
1200 w
luminous flux
110.000 lm
colour temperature
5.900° K
base
G 22
approximate lamp life
800 hours
Philips 1200 MSR/2
coemar cod.
105090/2
power
1200 w
luminous flux
110.000 lm
colour temperature
7.200° K
base
G 22
approximate lamp life
800 hours
4. Lamp: installation and replacement
27
English