Coemar Fiera 1200 Скачать руководство пользователя страница 5

Fiera

1200

utilises a Philips 1200 MSD, Philips 1200 MSR or MSR/2 1200W lamp with a G 22 lampbase.

The lamp is available from your 

coemar 

service centre:

The fixture’s internal temperature can reach 250° C after 5 minutes with a maximum peak of 350° C; ensure that the lamp is
cold prior to attempting removal. The fixture should be allowed to stand and cool for 10 minutes prior to its removal.
Both MSR and MSD lamps are part of the mercury vapour family of discharge lamps and must be handled with great care. The
lamps operate at high pressure, and the slight risk of explosion exists if operated over their recommended lamp life.
We recommend, therefore, that the lamp be replaced within the manufacturer’s specified lamp life.

installing the lamp

1) Using a Philips head screwdriver, loosen the 2 screws which affix the lamp assembly, located at the rear of the projector.

2) Remove the lamp assembly

Attention

Disconnect mains prior to opening up the unit.

Philips 1200 MSD

coemar cod.

105811

power

1200 w

luminous flux

92.000 lm

colour temperature

6.000° K

base

G 22

approximate lamp life

3.000 hours

Philips 1200 MSR

coemar cod.

105090

power

1200 w

luminous flux

110.000 lm

colour temperature

5.900° K

base

G 22

approximate lamp life

800 hours

Philips 1200 MSR/2

coemar cod.

105090/2

power

1200 w

luminous flux

110.000 lm

colour temperature

7.200° K

base

G 22

approximate lamp life

800 hours

4. Lamp: installation and replacement

27

English

Содержание Fiera 1200

Страница 1: ...1st edition october 2003 instructions manual 1a edizione ottobre 2003 manuale di istruzioni 1200...

Страница 2: ...assima rapidit e precisione Please note in the space provided above the relative service information of the model and the retailer from whom you purchased your Fiera 1200 This information will assist...

Страница 3: ...e lamp in the optical path and adjusting the beam 37 14 Turning on the Fiera 1200 without articulated movement 37 15 Resetting the counter 38 16 Automatic repositioning functions 38 17 Altering the op...

Страница 4: ...ls of the unit Isolate the projector from mains supply prior to performing any function which involves touching the internals of the unit including lamp replacement 2 For mains connection adhere stric...

Страница 5: ...ed lamp life We recommend therefore that the lamp be replaced within the manufacturer s specified lamp life installing the lamp 1 Using a Philips head screwdriver loosen the 2 screws which affix the l...

Страница 6: ...ed in the lamp s packaging The G 22 lampholder is sym metrical in construction DO NOT USE UNDUE FORCE In case of difficulty inspect for physical damage and then repeat the installation procedure 5 Sec...

Страница 7: ...g the fixture from lighting truss coemar has included two cam lock devices A The two cam lock devices may be instal led in 2 diverse positions on the base of the Fiera 1200 These devices are 1 4 turn...

Страница 8: ...ously affecting the proper ope ration of the fixture ambient temperature Never install the projector in locations where there is insufficient flow of circulating air the ambient temperature should not...

Страница 9: ...ioni di sicurezza WARNING High voltage inside Disconnect from power supply before opening A good ground connection is essential Case is very hot Do not install on flammable surfaces min Distance from...

Страница 10: ...ess each fixture Any number between 1 and 505 can be generated via the multifunction panel of the Fiera 1200 This procedure must be carried out on every unit When initially powered up each projector w...

Страница 11: ...e unit if accidentally knocked out of place opto OFF LAMP lamp control Lamp on off via DMX signal or lamp always on FANS fans control Fans speed control through PCB depending on ambience temperature S...

Страница 12: ...ure measurement 1 0 DMX value reading 255 DMX value reading enter o enter enter o o o o o TEMP temperature to measure the internal temperature in C DMIN DMX value on each channel reading of DMX value...

Страница 13: ...and holding the button and then pressing and holding down the button will cause the display to jump to the lowest possible value associated with the respective parameter MEAS TEST o o lampeggia enter...

Страница 14: ...ortional Tracking mode from fast to slow 128 247 50 97 proportional Tracking mode slow 248 255 97 100 6 no effect spare makes the light compatible with Electronic ballast version 7 no effect spare mak...

Страница 15: ...til a flat even beam is produced with no noticeable hotspot This procedure may be useful in situations where the Fiera 1200 may need to be switched on in an enclosed space such as in its flight case 1...

Страница 16: ...rating life of the projector have not been reset An encoder system based on 4 position indicators allows the Fiera 1200 to return to its correct position if it is accidental ly moved during operation...

Страница 17: ...h the projector will be sup plied when in use 1 Remove the screws on the base housing using a Philips head screwdriver as shown in the diagram below completely remove the cover thus providing full acc...

Страница 18: ...the unit 2 Select from either 208 230 or 240V by disconnec ting cable n 5 and moving it to the required volta ge To ensure a correct selection refer to the sticker located on the transformer Under no...

Страница 19: ...veral optional filters which can be utilised to alter the dimensions of the output of the projectors to suit specific lighting applications All the lenses and diffusion filters are rotatable thus allo...

Страница 20: ...g it 3 Remove the lense you intend to replace 4 Insert the new lense determining the rotated position you wish it to occupy Lenses are rotatable through 360 5 After installing the new lense reposition...

Страница 21: ...you should find it necessary to loosen the individual barndoors to adjust their position ensure that you retighten them suf ficiently to avoid them sagging 18 2 2 Rotating the barndoors 1 The barndoo...

Страница 22: ...y bump the unit NOTE this device may be deactivated see section 11 Display panel functions OPTO OFF to return to its correct position if it is accidentally moved during operation Whilst every possible...

Страница 23: ...here is a problem with the TILT Encoders Check the sensors and all associated cabling on the wheel which is used to determine the TILT movement in the yoke SNER LINE SYNCHRONISATION Error Check and re...

Страница 24: ...viso coemar reserves the right to effect modifications without notification manuale istruzioni instruction manual Fiera 1200 1 edizione ottobre 2003 1st edition october 2003 coemar spa viaInghilterra...

Отзывы: