![Coemar DR1 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/coemar/dr1/dr1_instruction-manual_2634371015.webp)
3.
Press the
remote
button on the display of the
DR1
; the display will show
D.REM
4.
By using the
+
or
-
buttons, scroll to the
SENS
option.
5.
Press the
enter
button; via the
+
or
-
scroll to
CON2
6.
Press the
enter
button; via the
+
or
-
scroll to
LIGH
7.
Press the
enter
button again and the sensor A will register the presence of light and the display will show
ON
if the lamp
is on and
OFF
if the lamp is off or there is an absence of light.
8.
Repeat the procedure with all the light sensors that need testing.
If the sensor does not register the presence of light and simply shows
OFF
it is either defective or badly connected.
temperature sensor (CON 2)
Via the
con2
connector you may test the correct operation of the temperature sensor within the projector as well as its connectors
and cabling. Locate the temperature sensor within the fixture and attach it to the
con2
connector of the
sensor test PCB
. By
heating up the sensor, the display of the
DR1
should display a temperature (for example
27
°
). If this is not the case, the sensor will
require replacement. Additionally, you may also test the connector and cabling by isolating the cable which connects the sensor to
the motherboard and attaching one end to the sensor provided with the kit and the other end to the
con2
connector of the
sen-
sor test PCB
and then moving the sensor close to and away from a heat source. By doing so, you should register a change in the
temperature displayed on the
DR1
. Should this not be the case, the cabling is damaged and will require replacement.
1.
Attach the
CON2
connector to the temperature sensor of your projector.
2.
Press the
remote
button on the display of the
DR1
; the display will show
D.REM
3.
By using the
+
or
-
buttons, scroll to the
SENS
option.
4.
Press the
enter
button; via the
+
or
-
scroll to
CON2
5.
Press the
enter
button; via the
+
or
-
scroll to
TEMP
6.
Press the
enter
button again and the sensor will register the temperature in degrees centigrade and the display will
show, for example,
27
°
.
7.
You should heat or cool the sensor to verify its operation and the changed display on the
DR1
If the sensor does not register a temperature or a change in temperature when heated or cooled, it may be defective and will requi-
re replacement.
AOO1
D . R E M
SENS
CON2
connettore 2
TEMP
sensore temp.
10
0
C
☞
enter
☞
remote
☞
+/-
☞
enter
☞
+/-
☞
enter
con2
Temperature sensor
Heat source
ON
lamp On
OFF
lamp Off
AOO1
D . R E M
SENS
CON2
connector 2
LIGH
light sensor
☞
enter
☞
remote
☞
+/-
☞
enter
☞
+/-
☞
enter
☞
+/-
32