background image

8. CONFIGURATION.

Values may be changed by using 

p

q

, changes can be saved by pressing 

ENTER

. If you wish to quit the configuration sequence,  

press 

MENU

.  Each time 

ENTER

 is pressed, the different screens, which display the sequence of configuration, will open 

automatically.

MENU

MENU

MENU

MENU

MENU

MENU

MENU

MENU

MENU

MENU

MENU

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

3”

3”

E

N

EN

Push 

MENU

 for 3 seconds 

.

to start configuration sequence

This temporary message gives information about the software version

Choose  language  using  the 
ENGLISH”, “LANGUE FRANÇAISE”, “LINGUA  ITALIANA” and “IDIOMA ESPAÑOL”.

p

q

 

keys:  PRACHE  DEUTSCHE”,  “LANGUAGE 

If there is no external device for detecting the minimum water level, press 

ENTER

 to 

confirm.  Otherwise, change NO  for  YES using the  

p

q

 

keys. 

In this step, the mode of operation can be selected using 

p

q

. There are 2 options:

n

On-off mode: only the start pressure is configured. The pump will start at this 
pressure - with the delay configured in the next step - and it will stop when  there is 
no flow demand. 

n

Pressure-dependent  mode:  the  start  and  stop  pressures  of  the  pump  can  be 
configured. 

The

 rated current intensity - from 0 to 10 A - is entered by means of the 

p

q

 

keys to 

enable thermal protection of the motor. This value is given on the name plate of the 
motor.  Press 

ENTER

 to confirm.

This is the start pressure for the pump. The desired pressure values within the respective 
range can be chosen using the  

p

q

 

keys:

n

On-off mode: from 1 to 5 bars.

n

Pressure-dependent mode: from 0 to 6,5 bar. 

This is the stop pressure for the pump in pressure-dependent mode. It must be within a 
range of 

1 to 7 bar and 1 bar above the start pressure.

Use  

p

q

 

to modify the values.

This is the delay to start the pump once it has reached the start pressure. Choose the 
desired timing using the 

p

q

keys.

This is the delay to stop the pump once it has reached the stop pressure. Choose the 
desired timing using the 

p

q

keys.

System is ready to operate. 
Press 

AUTOMATIC On/Off

, green LED is lit. 

From this moment the LCD screen will show:

n

On-off mode: current pressure (PLINE) and start pressure (PON).

n

Pressure-dependent mode:   current pressure (PLINE),   start pressure (PON) and 

stop pressure (POFF).

Using 

p

 in 

AUTOMATIC

 mode, it is possible to access a detailed expert screen  with the 

following parameters:

n

P line: current pressure.

n

INT: present current consumption.

n

F: position of the flow sensor (0: no flow, 1: with flow)

0

1

2

3

4

(1)

 (2)

6

7

8

9

10

    

INT. MAX.

LEVEL PROBE
NOT

OPERATING MODE
ON-OFF

OPERATING MODE
PRESSOSTATIC

PLINE        PON
05,0            03,0

PLINE    INT       F
05,0        9,0       1

START DELAY
00 sec

STOP DELAY
00 sec

P ON
05,0 bar

PLINE  PON  POFF
05,0     02,0    06,0

P OFF
06,0 bar

    

PLINE       PON

 

            

   03,0 bar    02,0 bar

LANGUAGE
ENGLISH

ONEMATIC
V 0.0

  

  OFF

7.  STARTUP. 

   

 

n

It is recommended to connect 

ONEMATIC

 to the electric supply via the motor protection switch. Wait for 5 seconds while the 

ONEMATIC

 is 

running autotest. 

n

If the unit is started for the first time, it will directly open the configuration menu. The LCD screen will display a message for language selection. 

Choose your language and start the configuration procedure - see 

7. CONFIGURATION

.

n

Once the unit is configured, switch  to manual mode by pressing the 

AUTO On/Off 

push-button (green LED off). Verify the rotational direction 

of the pump, and whether it is correctly primed using the 

Start/Stop 

 push-button. 

n

Press 

AUTO On/off

. The unit is ready to operate.

5

On
Off

(1) “

P ON”

 must be at least 0.2 bar higher than manometric pressure. 

Eg: with 20 meters of water column 

ð

 

P ON

 > 2.2 bar. 

The pump must be able to supply at least 0.5 bar more than “

P ON

”.

(2) Being in pressure dependent mode “

P OFF

” must be at least 0.5 bar lower than the pressure supplied by the pump.

Содержание Onematic

Страница 1: ...ual Simboli d avvertenza di questo manuale Avertissements inclus dans cette notice de service Risk by electric shock Riesgo de choque el ctrico Pericolo di scarica elettrica Danger par choc lectrique...

Страница 2: ...DE W L3 V L2 U L1 400 V 230 V Three phase motor Moteur triphas Motor trif sico Motor a tre fasi 3 phase power supply Raccordement r seau triphas Alimentaci n general trif sica Alimentazione elettrica...

Страница 3: ...nitoring the minimum water level in inlet tank This function is independent of the protective system against dry running and optional n Internal pressure transducer n Internal flow sensor n Control pa...

Страница 4: ...cations located on the connection strip base n Pumps with three phase motors n Power supply of control unit connect L1 L2 L3 via a three pole motor protection switch recommended in OFF mode and ensure...

Страница 5: ...reached the start pressure Choose the desired timing using the p q keys This is the delay to stop the pump once it has reached the stop pressure Choose the desired timing using the p q keys System is...

Страница 6: ...ped after the 4th attempt it will be switched off until the damage is repaired n Solution check the state of the pump for example the impeller could be blocked Verify the current value entered in the...

Страница 7: ...er It cannot be used for transport of other kinds of liquid It is recommended to use an accumulator in order to avoid continuous start stops due to the deterioration of taps valves and also to prevent...

Страница 8: ...ar las alarmas originadas por irregularidades o problemas del sistema que se indican en pantalla Su uso es opcional n Conexiones para detecci n de nivel m nimo de agua en dep sito de aspiraci n Este s...

Страница 9: ...i n adecuada a la potencia instalada siguiendo las indicaciones de laTabla 1 n Verificar la alimentaci n el ctrica Desmontar la tapa del circuito electronico y llevar a cabo las conexionesde acuerdo c...

Страница 10: ...archa Mediante las teclas p q se escogera el tiempo deseado Configuramos el retraso en desconectar la bomba una vez se ha llegado a la presi n de paro Mediante las teclas p q se escogera el tiempo des...

Страница 11: ...a por ejemplo que no haya ning n bloqueo del rotor etc Verificar que los datos introducidos en el menu de configuraci n respecto el consumo de la bomba sea el adecuado se recomienda entrar siempre una...

Страница 12: ...el transporte de otros l quidos Se recomienda utilizar un tanque de expansi n para evitar el deterioro v lvulas as como para evitar golpes de ariete en instalaciones con v lvulas de gran di metro ATEN...

Страница 13: ...n Connessioni per rivelamento del livello minimo d acqua nel serbatoio di aspirazione Questo sistema indipendente del sistema di sicurezza contro funzionamento a secco Il suo uso opzionale n Trasdutt...

Страница 14: ...sicurarsi che essiste una presa di terra efficace L1 L2 L3 e mediante interruttore magnetotermico adeguato alla potenza installata e in posizione di spento OFF n Motore Collegare il motore a U V W e n...

Страница 15: ...i sceglie il tempo desiderato Configuriamo il ritardo nello spegnere la pompa una volta raggiunta la pressione di fermata Mediante i pulsanti p q si sceglie il tempo desiderato Il sistema pronto per l...

Страница 16: ...pa per essempio che non abbia nessun blocco nel rotore ecc Verificare che i datti introdotti nel men di configurarzione rispetto del consumo della pompa sia adeguato si raccomanda mettere sempre un in...

Страница 17: ...vaso di espansione adeguato per ogni installazione con la finalit di evitare avviamenti innecesari dovuti a gociolamenti per deteriori inevitabili di rubinetti valvole ecc cos come per evitare possib...

Страница 18: ...surveillance du niveau d eau minimum dans la b che d alimentation Cette fonction optionnelle est ind pendante de la protection manque d eau n Capteur de pression int gr n Capteur de d bit int gr n Cla...

Страница 19: ...ions sur le bornier n Pompes quip es de moteur triphas n Alimentation de l appareil de commande r aliser le raccordement hors tension des conducteurs L1 L2 et L3 en pr voyant un disjoncteur moteur 3 p...

Страница 20: ...ouches p q 0 1 2 3 4 7 8 9 10 INT MAXI SENSEUR NIVEAU NON MODE OPERATION MARCHE ARRET MODE OPERATION MANODEBITMETRIQUE P MARCHE 05 0 bar PLINE PMARCHE 05 0 03 0 PLINE INT F 05 0 9 0 1 TEMP DEMARRAGE 0...

Страница 21: ...t n Solution contr ler l tat de la pompe La roue pourrait tre bloqu e par exemple V rifier la valeur d intensit r gl e dans le menu de configuration il est conseill de r gler l intensit une valeur de...

Страница 22: ...s filtres pour viter l obstruction du capteur de d bit Onematic est destin tre utilis pour l eau claire L appareil ne doit pas tre utilis pour d autres liquides La mise en uvre d un r servoir sous pre...

Страница 23: ......

Страница 24: ...130502D_v10...

Отзывы: