Page 7
3. Mechanical installation
The installer is responsible for safely and securely fastening the unit to the wall.
Note: When lifting the unit, it is important to place a protective underlay, to avoid scratching the base plate. The underlay
can consist of, e.g. thick cardboard or a similar material.
The mechanical installation involves
•
Marking, drilling of holes for connecting ducts and mounting of wall frame
•
Mounting of unit in wall frame
•
Installation of pipes and grates through walls or over roof, depending on model
•
Mounting of panels
Important: Before drilling holes in wall or roof, check that there is at least 0.5 m between the wall and the unit’s exhaust
end. If the exhaust end is facing out towards glass panes, that distance must be greater. If these minimum distances are
not observed, there is a risk of increased noise from the unit.
Simplified picture illustrating mounting of unit on wall frame.