https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1200-right-hand-programming-operating-instructions

• Remove the rear-fixing bolt and swing the lock over the edge of the door to reveal the battery compartment. 

• Remove one battery. 

• Press and hold the 5 button, replace the battery, the blue LED will flash twice, release the 5 button. Within three
seconds press the 5 button three times. The blue LED will flash twice and the lock will have reverted to the
factory master code 55 44 33 22 and all other stored settings will be erased. 

Penalty time 

• Entering three incorrect codes will cause the lock into shutdown for 10 seconds. 

Battery Power 

The KitLock should provide well in excess of 50,000 openings, of 4 seconds each, from 2 x AAA 1.5v cells. 

Low Battery 

When the battery power is low the Red LED will flash 3 times before the Blue LED flashes to signal acceptance
of the code. Batteries should be changed as soon as this happens. The lock will operate for 100 times with low
battery. 

 

 

Содержание KL1200

Страница 1: ...1 Master Code 55 44 33 22 2 User Code 00 99 When fitted immediately change the Master Code and User Code All Master Codes and Sub Master Codes are 8 digits long All User Codes are 4 digits long All Te...

Страница 2: ...only used for programming functions when lock is in Private Use Function Master Code Open the lock Change the Master Code Set Change Delete the Sub Master and User Code Select between Private and Publ...

Страница 3: ...e LED will flash twice and the lock will have reverted to the factory master code 55 44 33 22 and all other stored settings will be erased Penalty time Entering three incorrect codes will cause the lo...

Страница 4: ...ds Change the MASTER CODE Master Code 65 New Master Code New Master Code Example 55443322 65 12345678 12345678 Result Master Code has been changed to 12345678 Note prefix not required when in B Public...

Страница 5: ...Delete SUB MASTER CODE Master Code 63 63 Example 55443322 63 63 Result Sub Master Code deleted Note prefix not required when in B Public Use Sub Master Code Commands Change the SUB MASTER CODE Sub Ma...

Страница 6: ...PUBLIC USE with TECHNICIAN CODE enabled Master Code 50 Technician Code Technician Code Example 55443322 50 555555 555555 Result The lock is automatically set into function Public Use AND allows the p...

Страница 7: ...d it will once again relock for 4 hours If the lock is opened during the 4 hours period then the lock remains open until a new User Code is entered as normal Note This program will only work when the...

Страница 8: ...https codelocks zohodesk eu portal en kb articles kl1200 right hand programming operating instructions POI_KL1200RH v1_0318_OL 2019 Codelocks Ltd All rights reserved...

Отзывы: