p
Result: The lock will now revert to Private Use with the default User Code 0099 active until
reprogrammed.
Note: When the program is changed from Public Use above to Private Use, the locking pin should
now move to the locked position and previous single User Code erased. The # bar will now be
required for programming.
Restrict the LOCKED TIME
Special Note : The number of hours the lock can be set to remain locked is 2, 4, 6, 8, 10 or 12 hours.
On the KL1200 Right Hand version keypad this is set as follows:
2h=60, 4h=69, 6h=68, 8h=67, 10h=56
#Master Code
•
56
•
(Number of hours lock to remain locked)
••
Example: #55443322
•
56
•
69
••
Result: The lock will auto open after 4 hours. If a new User Code is entered it will once again relock
for 4 hours. If the lock is opened during the 4 hours period then the lock remains open until a new
User Code is entered as normal.
Note: This program will only work when the lock has been set into Public Use Function.
Set lock in TECHNICIAN MODE
#Master Code
•
50
•
Technician Code
•
Technician Code
••
Example: #55443322
•
50
•
555555
•
555555
••
Result: The lock set into Technician Mode with Technician Code 555555
Note:
1. Technician Code only available when lock is set in B) Public Use
2. The Technician Code is able to open the lock without the entered User Code being erased.
3. Opening the lock with the Master Code will erase the User Code.
Delete the TECHNICIAN CODE
#Master Code
•
54
•
54
••
Result: Technician Code deleted
Disable/Enable SOUNDER
Note: the default is for the sounder to activate at every button press. To disable the sounder enter the
following toggle code string:
#Master Code
•
59
•
59
••
Result: No sound when button pressed. To enable the sounder repeat above code sequence.