4/14/2016
D014465 CR1400 CR1000 CR2300 CR2600 CR3600 CR44X5 CR8000 CR900FD CR6000 CR5000 T500 Client Version ICD
Page 95 of 106
© 2013-2016 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg Setting Name
Default (Hex)
Comment
2E2 Out-of-Stand
Illuminate-on-Motion
0
0: Disabled
1: Enabled
When the reader is placed on a surface and Stand Detection is
enabled, register 2E3 will be set to the value in this register.
Note: Applies to CR5000 & CR5000RTC readers only.
Keywords: #Stand, #StandModes
2E3 Illuminate-on-Motion
0
0: Disabled
1: Enabled
If set to 1, switches out of “quick decode” mode for a period of
time (the illuminate-on-motion time) when motion is detected.
Otherwise, motion does not affect the “quick decode”
behavior.
Note: Applies to CR5000 & CR5000RTC readers only.
Keywords: #Stand, #StandModes
2E4 Illuminate-on-Motion
Duration (ms)
3E8
(#1000)
Valid Range: 0 to 7FFFFFFF (#2147483647) Milliseconds
Period of time that “quick decoding” will be disabled and
illumination will occur after detecting motion if Illuminate on
Motion is enabled.
Note: Applies to CR5000 & CR5000RTC readers only.
Keywords: #Stand, #StandModes
2E5 Stand Alone Age
Verification Primary
Age
15
(#21)
Valid Range: 0 to 100 (decimal practical limit)
The value used to indicate if the age of the holder of the
document is above or below this age.
Note: Applies to CR5000RTC readers only.
Keywords: #AgeVerification
2E6 Stand Alone Age
Verification Secondary
Age
0
Valid Range: 0 to the value of Stand Alone Age Verification
Primary Age (2E5)
The value used to indicate if the age of the holder of the
document is below the Stand Alone Age Verification Primary
Age but above or equal to this age. The value will be ignored if
0 or larger or equal to Stand Alone Age Verification Primary
Age.
Note: Applies to CR5000RTC readers only.
Keywords: #AgeVerification