Reg Setting Name
Default (Hex)
Comment
2C2 In-Stand Default Event
FF
(#255)
CR2300:
CR2600:
CR2600XHD:
CR3600:
CR3600DPM:
F0 (#240)
CR5000:
CR5000RTC:
6
When the reader is placed in the stand (for CR5000 &
CR5000RTC, when it is placed on a surface) and Stand
Detection is enabled, register C4 will be set to the value in this
register.
See register C4 for a list of events.
Note: Applies to Bluetooth® and CR5000 & CR5000RTC readers
only.
Also see registers: 1F7 to enable Stand Detection, 2AB to
define the charging base as a ‘Stand’ and C4 for a list of events
Keywords: #DefaultEvent, #StandModes
2C3 Out-of-Stand Default
Event
FF
(#255)
CR5000:
CR5000RTC:
2
When the reader is removed from the stand (for CR5000 &
CR5000RTC, when it is lifted up) and Stand Detection is
enabled, register C4 will be set to the value in this register.
See register C4 for a list of events.
Note: Applies to Bluetooth® and CR5000 & CR5000RTC readers
only.
Also see registers: 1F7 to enable Stand Detection, 2AB to
define the charging base as a ‘Stand’ and C4 for a list of events
Keywords: #DefaultEvent, #StandModes
2C4 Minimum Motion
Illumination Percent
1
CR3600DPM:
CR6000:
3
Valid Range: 0 to 64 (#100) Percent
This is the minimum illumination that will be used when in
motion detection mode.
Also see register: 206
Keywords: #MotionDetection
2C5 Minimum Initial
Battery Percent to
power iPhone
5
Valid Range: 0 to 64 (#100) Percent
In iPhone communication modes (Apple® App mode and
Apple® Keyboard mode, currently) the reader will not provide
any power or communication channel to the iPhone until it has
confirmed that the sled battery is above this percent.
Note: Supported on CR4405 only.
Keywords: #Battery