4/14/2016
D014465 CR1400 CR1000 CR2300 CR2600 CR3600 CR44X5 CR8000 CR900FD CR6000 CR5000 T500 Client Version ICD
Page 60 of 106
© 2013-2016 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg Setting Name
Default (Hex)
Comment
CE
Codablock F Symbology 0
0: Disabled
1: Enabled
Note: This register has no effect on a CR900FD without the
proper 2D barcode decoding license.
CF
Macro PDF417
Symbology
0
0: Disabled
1: Enabled
Note: This register has no effect on a CR900FD without the
proper 2D barcode decoding license.
Keywords: #PDF417
D8
Composite Barcodes
Require Both Elements
1
0: Accept any composite element
1: Only accept composite barcodes if both elements could be
decoded.
Keywords: #CompositeBarcodes
D9
Max Connection Wait
Time
CR2300:
CR2600:
CR2600XHD:
CR3600:
CR3600DPM:
0F (#15)
CR4405:
5
Valid Range: 0 to 7FFFFFFF Seconds
The Reader will attempt connection for up to this amount of
time when a connection is explicitly requested, such as when a
QuickConnect Barcode is read or an upload is requested (by
event or command).
Note: Only applies to readers using Bluetooth® communication
modes.
DB
Merge Selected
Decodes
0
0: Disabled
1: Enabled
When enabled, multiple valid decodes from a single read are
concatenated. This includes Composite barcodes or when
multiple barcode reading is enabled.
Keywords: #CompositeBarcodes
E3
Trigger 1 Confirmation
Time (ms)
0
Valid Range: 0 to 7FFFFFFF Milliseconds
The trigger input must be asserted for this amount of time
before the trigger event is generated. Setting this value > 0
makes it easier to select combinations of triggers (e.g. trigger
3, which is trigger 1 & 2 asserted together).
E4
Trigger 2 Confirmation
Time (ms)
0
Valid Range: 0 to 7FFFFFFF Milliseconds
The trigger input must be asserted for this amount of time
before the trigger event is generated. Setting this value > 0
makes it easier to select combinations of triggers (e.g. trigger
3, which is trigger 1 & 2 asserted together).