EU Lock Feature
By setting either Dip switch #8 or Dip switch #9 to the “on” position, the EU Lock Feature is enabled. This feature ensures
that at least a certain Light Level is on while any siren tones, except Air Horn, are on. If the siren is turned on without the
minimum Light Level on, then that Light Level will turn on. If later that Light Level is turned off, then the siren will also turn
off if it is still on. The minimum Light Level is set by the following table:
For Example: If EU Lock Level 1 is enabled (by setting Dip switch #8 “ON”, and Dip switch #9 “OFF), then at least
Light Level 1 will always be on while the siren is on. If the siren is turned on and no lights are on, then Light Level
1 will also turn on. When Light Level 1 is turned off, then the siren will also turn off if it is still on.
Auto Siren Feature
By setting Dip switch #2 to the “on” position, Auto Siren is enabled. In this mode, the SIR1 siren tone will automatically turn
on when Lighting Level 3 is turned on. When Lighting Level 3 is later turned off, any siren tone that is on will also shut off.
The SIR1 siren tone may be programmed as described below.
Programmable Siren Tones
The SIR1 and SIR2 are user programmable. They are preset at the factory as such: SIR1 – Wail and SIR2 – Yelp, To
change the factory preset, depress and hold the STBY button, then depress/release the desired SIR button to go to the next
available tone. Once the desired tone is chosen, release both buttons. Repeat for the other SIR buttons.
Programmable Air Horn Pitch Tones
There are two tones available for the Air Horn. To change, depress and hold the STBY button, then depress/release the Air
Horn button. Once the desired tone is chosen, release both buttons.
Auxiliary Light Control Buttons
There are four auxiliary light control buttons that the user can use as desired. To operate, depress/release once and the
desired feature will be enabled. Depress/release again and the feature will be disabled. The AUX3 and AUX4 buttons have
special modes they can operate in that can be enabled with Dip switches. If these modes are not set, AUX3 and AUX4
operate in default mode, which is the same as the other AUX buttons. Below is a description of these two modes.
AUX3 - Momentary Active Mode
When Dip switch #3 is “on”, the AUX3 channel is only active while the AUX3 button is pressed. Once released, the
AUX3 channel will become inactive again.
AUX4 - Gun Lock Mode
When Dip switch #5 is “on”, pressing the AUX4 button will cause the AUX4 channel to become active for 10 sec-
onds. After 10 seconds, the AUX4 channel will become inactive again.
Keypad Backlight Shut Off
For daytime applications, or applications that require no light output, the blue/red lighting on the keypad may be shut off.
This is accomplished by holding the STBY button down for 5 or more seconds without pressing any other buttons on the
keypad. To turn keypad lighting back on, hold the STBY button down for 5 or more seconds without pressing any other
buttons on the keypad.
California Title 13 Compliance
By setting Dip switch #1 to the “on” position, the 3599L5 operates in a California Title 13 Compliance mode. In this mode,
Hyper Yelp, Hi-Lo, Hyper-Lo, and Whoop siren tones are disabled. In addition, the Air Horn is disabled if Light Levels 2 or
3 are on.
8
OPERATION MODE
EU Lock Disabled
EU Lock Level 1
EU Lock Level 2
EU Lock Level 3
Dip switch #8
OFF
ON
OFF
ON
Dip switch #9
OFF
OFF
ON
ON
Содержание 3599L5
Страница 11: ...11 2 1 3 4 5 6 7 8 10 11 14 13 12 15 9 16 17...
Страница 15: ...NOTES 15...