Frequency Response
@ 4
Ù
load with 120 W ouptut power
20 Hz – 20 kHz: ± 0,07 dB
THD+N over frequency
20 Hz
@ 4
Ù
load with 120 W output power
Damping Factor
>400
8
Ù
load, 1 kHz and below
Input Impedance
12 k
Ù
balanced
Input Gain
32 dB
Maximum Analogue Differential Input Level
+18 dBu / 6,16 Vrms / 8,70 Vp
Minimum Loudspeaker Load Impedance
lower values are safe, but out of specification
Zmin = 2
Ù
for Dual-Channel operation
no performance guarantees can be given when driving lower impedances than specified
Protection Circuits
Inrush-current limitation, protection circuits against power on / off transients, temperature
monitoring of transformers and heatsinks, output DC protection, temperature dependent
SOA protection, intelligent mains fuse protection, SMPS overload protection, overcurrent
limitation
Limiters
Selectable FuseProtect Limiter
Cooling
Two temperature dependent speed-controlled axial fans
LED Indicators
LEDs for Sensor, Protection, Limit, Signal, Ethernet and LINET
Input Connectors
Two 3-pin XLR female analogue input connectors, pin 2 = hot (inphase)
Two 3-pin XLR male passive loop through connectors
Two LINET network connectors (in and out) RJ45
Power Output Connectors
®
One 4-pole SPEAKON connector for each output channel (bi-amping possible)
Modes of Operation
Dual channel (Stereo)
Input Sources
Analogue, LINET (AES/EBU)
A/D – D/A Converters
24 bit / 96 kHz
We reserve the right to make technical alterations without prior notice
5 SPECIFICA
TION
Two Ethernet Link connector RJ45 marked Prim/Sec
One AUX RJ45 and One DAN RJ45
– 17 kHz: <0,1%
One 5-pin XLR female sensor input
CODA AUDIO
LINUS 10
USER MANUAL v1.0
CODA AUDIO LINUS10