4 OPERA
TION
Linus10 Master #01
P 14:ViRAY-A G
I 1_LF 1_HF
G 0.0 0.0
Preset
Group Parameter
Linus10 Slave #01
P 14:ViRAY-A G
I 1_LF 1_HF
G 0.0 0.0
3. Preset Select
- Go to position “P” by using the rotary encoder knob on the Master
- Choose Preset and push to enter selection. Slave amplifier will change the preset automatically.
“G” (Group Parameter) needs to be deleted to unlock preset change and tuning option
Attention:
Slave lose group parameter. Any time you change
the preset all tuning parameters will be deleted!
4. Input Signal Routing
- Position “I” – enter selection on the corresponding output channel and push again to confirm.
• route the signal to the channel
• select the input signal type (Analogue or Digital)
Linus10 Master #01
P 14:ViRAY-A G
I 1_LF 1_HF
G 0.0 0.0
Linus10 Slave #01
P 14:ViRAY-A G
I 1_LF 1_HF
G 0.0 0.0
Input
Input
Important:
Signal routing is preset dependant! Example:
ViRAY-P – 4 input channel individual
LA12 – 1 input channel
Input Signal Chart
:Analogue Inputs: A, B, C, D
LINET (digital) Inputs: 1, 2, 3, 4, 5, 6, 7, 8
Please note: Depending on the Preset structure, Gain, Delay, Tuning
needs to be set on Master and Slave units.
CODA AUDIO
LINUS 10
USER MANUAL v1.0
CODA AUDIO LINUS10
P. 21