P.14
2.5 Factory settings
LINUS10
amplifiers are delivered with the following factory settings
Power Status
Amplifier is switched Off
Input Selection
Analog
AmpGain
32 dB
Output Mode
Dual Channel
Mute
Both channels inactive (muted)
Level Attenuator
0 dB both channels
Clip Limiter
On
DSP
On
Lock Device
Unlocked
Ethernet Settings
192.168.1.1
Ethernet Mask
255.255.0.0
Ethernet Gateway
192.168.1.1
FuseProtect level
24A (can be switched to 18A)
3.1 Mounting
Use four screws and washers when mounting the amplifier to the front rack
rails. For mobile use, the amplifier should also be secured using the 19”
mounting elements on the rear panel.
2 THE AMPLIFIER / 3 INST
ALLA
TION
USER MANUAL v1.0
CODA AUDIO LINUS10
Change FuseProtect level:
Move to Device Information Page on the display
Press „ESC“ Button for min 2 Seconds, hold it and press
aditionally:
UP Button: Strong Fuse (24A)
DOWN Button: Weak Fuse (18A)
Amplifier needs to be rebooted